Safety Instructions
5
1.2.2. Protection Circuits
There are several protection circuits used in the amplifier. They are activated when one or more
parameters exceed defined values or some unwanted condition occurs.
• VSWR too high
• Anode current too high
• Anode voltage error
• Screen current too high
• Screen voltage error
• Grid current too high
• Grid voltage error
• Heating voltage error
• Mistuning of PA
• Temperature too high
• Soft start for fuse protection
• “switch-on blocking “ at opened amplifier
1.2.3. Features
The manufacturer implemented some of the company’s newest development results with most
wanted operating and safety features into this new model:
• High level of protection
• Memory for faults and warnings, easy maintenance
• Automatic set-up anode current (BIAS) – no need to adjust manually after changing the
tube
• Three programmable working modes of the centrifugal blower ( turbine ) + axial blower
• Full QSK with silent relay
• Many operational parameters to display
• Easy transport due to detachable HV transformer
1.2.4. The Advantages of OM40001A
• Full compatibility with: ICOM, ELECRAFT, KENWOOD, TEN-TEC ORION, YAESU, Icom
transceive protocol using by MicroHAM devices ( CI-V output ), FLEX Radios and
Anan.
• RF sensitive Band and Frequency switching, for use with radios which do not have
CAT. We recommend using CAT and BAND DATA information due to the much faster
band changing whenever possible.
• Automatic switching between bands. Automatic tuning within the band according to segments.
• Automatic switching of Band Pass Filter – BAND DATA output compatible with YAESU radios (BCD code).
• Automatic switching of Antenna switches. The maximum number of antennas is 10, controlled by BCD
output code.
• Remote control via available PC Application. http://www.om-power.com/download/HF PA_Manager_