EBS level means level of the Input power where EBS starts working. Default EBS value is 0.1 W. We
recommend turning EBS ON. A significant feature of using EBS is PA operating temperature reduction.
NOTE: If you are not using compression in your TCVR, or you are not speaking loud enough, some
syllables can be cut off. In such a case you should turn OFF the EBS.
The next two settings allow
deletion of the manual user
settings of the amplifier tunings for
a single band or for all bands.
Settings in all segments will return
to the factory default values (for 50
Ohms).
In the next line you can define
working mode of the blower. In the
first mode speed depends on the
PA temperature (TEMP), In PTT
mode the speed increases to
maximum, and the ALLWAYS mode
means maximum speed all the time
during PA operation
(recommended for DIGI modes).
Press SAVE to write the mode to the memory.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.