Certifications 2

No: QA-TR-91349
1 / 4
S031, -7, 2016/12/01
Tohoku Murata Manufacturing Co., Ltd.
1-1 Shimosugishita, Takakura, Hiwada-machi, Koriyama-shi, Fukushima, 963-0531 Japan
Phone: +81-24-955-7770 / Fax: +81-24-955-7884
SAFETY DATA SHEET
1. Product and Company Identification
Product Information
Company Name : OLYMPUS Corporation
Product Category : Lithium Ion Polymer Rechargeable Battery Pack (Single Cell Battery)
Model Name : LI-92B / SP87YOPN2YC
Rated Capacity : 1350 mAh ( 4.9 Wh )
Average Operating Voltage : 3.60 V
Company Identification
Supplier’s Name : Tohoku Murata Manufacturing Co., Ltd.
Supplier’s Address : 1-1 Shimosugishita, Takakura, Hiwada-machi, Koriyama-shi, Fukushima,
963-0531 Japan
Information Telephone : +81-24-955-7770
Date Prepared : Jan. 01, 2019
Signature of Paper :
2. Hazard Identification
Class Name : Not applicable for regulated class
Hazard : It may cause heat generation or electrolyte leakage if battery terminals contact with other
metals. Electrolyte is flammable. In case of electrolyte leakage, move the battery from
fire immediately.
Toxicity : Vapor generated from burning batteries, may make eyes, skin and throat irritate.
3. Composition / Information on Ingredients
IMPORTANT NOTE:
The battery pack uses one SP873440N lithium ion polymer rechargeable cell and control circuit on the PWB.
The battery pack should not be opened or burned since the following ingredients contained within the cell that
could be harmful under some circumstance if exposed or misused.
The cell contains neither metallic lithium nor lithium alloy.
Common chemical name / General name CAS number
Concentration /
Concentration range
Lithium Nickel Cobalt Oxides (active material) 113066-89-0
2545%
Polyvinylidene Fluoride (binder) 24937-79-9
0.53%
Carbon black (conductive material) 1333-86-4
0.11%
Graphite (active material) 7782-42-5
1030%
Organic Solvent (gel type electrolyte) N/A
520%
Others N/A
2050%
UN number : UN3480
Watt-hour rating : 4.9 Wh for battery pack
4. First Aid Measures
The product contains organic electrolyte. In case of electrolyte leakage from the battery, actions described below
are required.
Eye contact : Flush the eyes with plenty of clean water for at least 15 minutes immediately, without
rubbing, and call a doctor. If appropriate procedures are not taken, this may cause an eye
irritation.

Summary of content (4 pages)