Installation & Assembly
Exploded Drawing:
* Note: Please specify nish/color when ordering.
ITEM # DESCRIPTION
A OP-490011 3/32” Allen Wrench
B OP-190015C,H* Lever Handle-Cold, Hot
C OP-430027* Escutcheon & Gasket
D OP-490006 Bonnet Nut
E OP-330002C,H Ceramic Disc Cartridge-Cold,Hot
F OP-590002 Valve Mounting Kit
G OP-590001 Supply Nut
H OP-490008 Flex Connector Hose
I OP-490009 “Y” Connector & Washer
J OP-430001 Spout Mounting Kit
K OP-230005* ‘J’ Style Spout
L OP-630004* 50/50 Pop-Up Drain Assembly
(For L-7470)
M OP-630002* Brass Pop-Up Drain Assembly
(For L-7472)
1 OP-490029 3/32” Allen Screw
2 OP-490010* 1.5 GPM Aerator
3 OP-430028 Washer
For more care information or trouble shooting
inquiries about your Olympia product, Please call:
OLYMPIA FAUCETS, INC. (888) 772-7701
7AM - 8PM EST (4AM to 5PM PST)
www.olympiafaucets.com
(6) Push rod down to open drain. Insert
the drain plug carefully. Test to ensure the
drain plug is working properly
(7) Connect lift rod strap to the rod by
using clip. Tighten the thumbscrew to
connect lift rod strap to pop-up lift rod.
(5) Remove rod nut. Insert rod. Tighten
the rod nut.
(4) Remove the excess putty. Connect the
trap (check manufacturer’s instructions for
installation).