Datasheet

BOARD LAYOUT:
POWER SUPPLY CIRCUIT:
Power should be applied to CON2PV2-2.5MM connector. AVR-CAN could be
powered by applying up to 12VDC (7 to 12 VDC) to EXT1-1 and EXT1-2 and GND
to EXT1-3 and EXT1-4 or if you supply 7 to 12 VDC to CON2PV2-2.5MM pin 2
(VIN) and GND to CON2PV2-2.5MM pin 1 .
The consumption of AVR-CAN is about 40-50 mA.
RESET CIRCUIT:
AVR-CAN reset circuit is made with R6 (10k) pull-up and button RST. On the
board there is a place for the voltage supervisory device MCP120-T, but we sell it
without MCP120-T.