Set the LED indicator ON and OFF through "Led Marquee", and click "Set
Configs" to confirm;
Set the ON and OFF of the LiDAR safety function through "Safe Area", and click
"Set Configs" to confirm;
Select input mode of "safe bank" trough "Safe bank input";
Set the mode of the LED indicator through "Led Mode";
Select current Bank through "Safe bank config" when "Safe bank input" is
“Software”;
Set receiving computer IP and port through "Host IP & Port".Up to 3 groups can
be set. Click to add a group, click to delete a group.
Enable/disable the DHCP function: the LiDAR dynamically obtains an IP address
from the DHCP server (ON), and the LiDAR needs to set up a static IP address
(OFF);
Modification of LiDAR IP: Enter the new IP into the LiDAR IP column (must be in
the same network segment as the local IP), click the "Set Network" to confirm, and
the modification is complete after the LiDAR is powered on again
Figure 9 Parameter configuration of web page
6.2. Parameter configuration of filter level
The web page parameter configuration method is as follows:
Open the browser (please use Chrome, Firefox, Edge or other standard browsers),
enter http://LIDAR IP/advanced.html; (the factory default address is:192.168.1.100)
Over range as: Select the point that exceeds the range to output as the maximum
range or display as 0;
Weak points filter: set the strength of weak point filter ;