OMEN-1BS2- 202012

User ManualLR-1BS2
OMEN-1BS2-202012
11
The corresponding relationship between the security field group (BANK) and the switch
value of the input (Input) port of LR-1BS2 is shown in the following table.
indicating low level, indicating high level.
Table 4 The relationship between field group and input port switch
Note:Only one group of BANK is valid at any time
Bank 0 is activated if I/O port is not connected;
BANK 15 is activated if I/O port is only connected to VCC and GND;
After the I/O port is connected to VCC and GND, connect the input port to signal access
by referring to above table, and the corresponding Bank group is activated.
Field group
Input Signal
Bank code
BANK 0
Input:□3210
0000
BANK 1
Input:□3210
0001
BANK 2
Input:□3210
0010
BANK 3
Input:□3210
0011
BANK 4
Input:□3210
0100
BANK 5
Input:□3210
0101
BANK 6
Input:□3210
0110
BANK 7
Input:□3210
0111
BANK 8
Input3210
1000
BANK 9
Input3210
1001
BANK 10
Input3210
1010
BANK 11
Input3210
1011
BANK 12
Input3210
1100
BANK 13
Input3210
1101
BANK 14
Input3210
1110
BANK 15
Input3210
1111