Printer User Manual
Table Of Contents
- 6020e_4.pdf
- In This Section
- Chapter 1Introduction
- Overview
- Software Requirements
- Network Preparation
- Before You Start
- Overview of TCP/IP Configuration
- Chapter 2 Configuring the OkiLAN 6020e
- Choosing an IP Address
- Configuring the OkiLAN 6020e
- Assigning the IP Address
- Other Utilities
- Verifying Access to the OkiLAN 6020e
- Chapter 3 TCP/IP Configuration and Printing
- Overview
- Configuring for TCP/IP Network Printing
- Remote Print Queue Name
- Configuring a BSD-Style Print Queue
- Remote LPD Printing
- FTP Printing
- Timeout Checking
- Raw Port Printing
- Chapter 4 OkiNet for TCP/IP
- Overview
- System Requirements
- Running OkiNet for TCP/IP
- Configuring the OkiLAN 6020e Using OkiNet for TCP/IP
- Configuring TCP/IP Options
- EtherTalk Configuration Options
- Output Port Configuration Options
- SNMP Configuration Options
- Enabling/Disabling Protocols
- SNMP Trap Configuration
- Saving the Configuration
- Displaying OkiLAN 6020e Diagnostic Information
- Printing a Configuration Sheet
- Resetting the OkiLAN 6020e
- Restoring Factory Default Settings
- Creating Customized Views
- Modifying View Settings
- Permanently Defining SNMP Access Information
- Configuring the Discovery UDP Port Number
- Starting a Telnet Session
- Starting the BOOTP Server
- Chapter 5 Web Configuration
- Chapter 6 Telnet Configuration
- Overview
- Running a Telnet Session
- Appendix A Troubleshooting
- Main Status Indicator
- Restoring the OkiLAN 6020e to Factory Defaults
- Unable to Assign IP Address
- Hardware Error Messages
- Printing a Configuration Page
- Unable to Print
- Appendix B Application Considerations
- Overview
- Assigning the OkiLAN 6020e IP Address with BOOTP
- Configuring the OkiLAN 6020e IP Address with RARP
- Configuring HP-UX v8.07 for Printing with the OkiLAN 6020e
- Configuring HP-UX v9.xx for Printing with the OkiLAN 6020e
- Configuring HP-UX v10.xx for Printing with the OkiLAN 6020e
- Configuring SCO UNIX for Printing with the OkiLAN 6020e
- IBM's AIX ver. 3.x for Printing with the OkiLAN 6020e
- Configuring Solaris 2.x for Printing with the OkiLAN 6020e
- Configuring Sun-OS v4.1.x or Ultrix v4.2 for Printing with the OkiLAN 6020e
- Appendix C Internet Printing Protocol (IPP)

IV - 58
Section 4 - Appendix B - Application Considerations
OKI OkiLAN 6020e User’s Guide
A name can be arbitrarily assigned to any device on a
network. The following examples use the name
OKIPRINTER. Remember that this name is arbitrary; a
customer can assign any name they wish.
/etc/bootptab: The “/etc/bootptab” file has entries
where each entry maps a network
hardware address to an IP address.
Example: OKIPRINTER:\
ht=ether:\
ha=0040681750A4:\
ip=192.168.42.55
The ht signifies hardware type. For the OkiLAN 6020e,
it will always be ether for an Ethernet device and token
for a Token-Ring device. The ha signifies the network
hardware address. For BOOTP, the network hardware
address must be represented without the colons
between each byte. The ip part of the entry is where the
IP address is specified. There are several other
parameters that can be specified in a bootptab entry.
However, the three parameters shown here are the only
ones required for OkiLAN 6020e installation.
The following sequence of events occurs during the
power up of the OkiLAN 6020e using BOOTP.
1. An OkiLAN 6020e powers up but does not know its
IP address. (It does know its network hardware
address.)
2. The OkiLAN 6020e sends out a BOOTP request
packet with its network hardware address. For this
example, the network hardware address is
00:40:68:17:50:A4.
3. The bootpd daemon running on a BOOTP server
(which in this example is a UNIX workstation) sees
the BOOTP request along with the network
hardware address. It looks up the network hardware
address in the “/etc/bootptab” file. The bootpd
daemon finds the associated IP address of the device
in the bootptab file.