BVX-200 Fume Extraction System BVX-200 System User Guide……………………… page 3 Guide de l'utilisateur du système BVX-200……….. page x BVX-200 Benutzerhandbuch……………….……….. page x Sistema BVX-200 – Guida per l’utente……..……... page x Guía del Usuario del Sistema BVX-200……….…… page x BVX-200 ㋏㒳Փ⫼䇈ᯢ……….…………………………page x www.okinternational.
Operations Manual & User Guide Congratulations on your purchase of the BVX-200 Fume Extraction System. It is designed to protect your health from hazardous and irritating air pollution you may have at your work area. It has been designed and manufactured to the highest quality standards. This document has been prepared to guide you with the setup, operation, and user maintenance of your system. We recommend that you review it to optimize performance and for your safety. Contents Page No. 1.
1.0 Please Observe The Following 1.1 Emphasized Sections Warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged. Note: Gives recommendations for better handling of the unit during operation or adjustment as well as for service activities. 1.
1.3 Unpacking and Inspection Carefully unpack the Fume Extraction System and examine the items contained in the Carton. Inspect the unit for any damage that might have occurred in transit. If such damage is present, notify the carrier immediately. Claims for damage must be made by the consignee to the carrier and should be reported to the manufacturer. 1.4 Items supplied 1 1 1 1 Filter Unit with filters installed Remote Start/Stop Button Power Cord Operating Manual 1.
1.6 Usage The Fume Extraction System is a portable, two-station filtration system for the removal of fumes, light dust or vapors at the work place. The filter set supplied with the filter unit depends on the model ordered. Model BVX-201 supplied with a pre-filter and a main filter. The main-filter is a combo-filter consisting of a HEPA filter with an efficiency of 99.95% at 0.3 micron and an activated carbon filter.
2.0 Description 2.1 Operating Elements and Construction Air Inlets: 63mm OD 50mm ID ESD Safe Housing Filter-blocked alarm sounder Mains Input Filter Cover Latch (front and back). Pull from bottom to open. Remote switch Main On/Off Switch Remote switch jack socket 2.2 Theory of Operation The efficient removal of hazardous fumes at your workplace is a two-step process: fume capture and filtration. The filter unit is supplied with a set of filters already installed.
3.0 Technical Data Maximum airflow, free blowing............................. 250m3/h (150cfm) Flow rate .............................................................. 2 x 75 m3/h (45cfm) Static pressure ..................................................... 850 Pa (3.5”WC) Noise level (approx.) ............................................ < 55dBA Voltage ................................................................. 100 – 240 VAC, 1 phase Frequency ........................................................
5.0 Maintenance and Cleaning 5.1 Filter Unit - Maintenance and Safety The BVX-200 Fume Extraction System is designed with low maintenance in mind. The housing is ESD safe plastic. Here are a few tips to keep your system running in top shape: To clean, use a light wipe with a gentle cleaner to prevent build up of particulate and flux residue (be sure unit is turned off while cleaning).
Warning! Do not attempt to clean filters. Attempted cleaning can damage filters and cause potential risk to health and equipment. Note: OK International recommends replacement of filters annually as a minimum. Use only original replacement filters. Model BVX-203 This model features a deep-bed gas filter, which generally does not clog and reduce airflow as common with HEPA filters. Replace both filters; pre-filter and carbon filter as soon as odors become noticeable.
5.4 Filter Replacement Procedure: 1. Turn unit off and disconnect the power cord. 2. Unlatch both filter cover catches and remove the filter cover. (see below) 3. Replace the filters. (Pre-filter/main filter). Ensure the main filter is placed inside the alignment pins so that the interlock switch is depressed. 4. Replace the filter cover and ensure a proper fit to the bottom housing. Hook both latches into the filter cover and press down carefully to engage each latch to the base.
6.0 Ambient Temperature Alarm Calibration The BVX-200 filter-block alarm is factory calibrated to a specific temperature setting and will, for most users, require no adjustment. However, users in warmer climates may need to adjust the BVX-200 temperature setting to prevent false alarms. Details are available from your local OK International representative. 1 Assemble the BVX-200 as per the User Guide. Both the remote switch the main power switch should be in the ‘Off’ position.
7.0 Troubleshooting Problem Possible Cause Check No air flow No Power Poor performance Air leak Check On/Off Switch Check power outlet Check power cord Check filter is present Check safety interlock switch Check hose/arm for leaks Check hose/arm for proper installation Check hose/arm for partial clogging 8.0 Part Numbers 8.1 Filter Units BVX-201 ....................................Filter Unit for 2 Station, Pre / HEPA / Gas BVX-203.....................................
9.0 WARRANTY Please visit OK International's products web page (www.okinternational.com) where you will find available information on systems, accessories, technical notes, and more. You may also contact your local representative for pricing and availability. OK International warrants the BVX-200 Series against any defects in materials or workmanship for one (1) year from the date of purchase by the original owner.
10.0 CONTACT INFORMATION For Sales & Customer Care North America OK International 12151 Monarch Street Garden Grove, CA 92841 USA Tel: +1 714-799-9910 Fax: +1 714-799-9533 www.okinternational.com Europe OK International Ltd. Eagle Close, Chandlers Ford Hampshire, SO53 4NF U.K.