Order Number : GETEC-C1-16-414 FCC Part 15 Certification Test Report Number : GETEC-E3-16-052 Page 1 / 1 APPENDIX G : USER’S MANUAL EUT Type: Stream Injector Output Device FCC ID.
DMS-OUT Owner’s Manual Universal Remote Control www.UniversalRemote.
DMS-OUT Owner’s Manual Overview The DMS-OUT allows 3rd party devices access to the streaming sources in the DMS Audio Network. For example, this device is the perfect solution for adding any new/existing 3rd party AVR, soundbar, or other audio device to the DMS Audio Network. Table of Contents Features and Benefits.........................................1 Parts & Pieces......................................................1 Online Help: www.urccontrolroom.
DMS-OUT Owner’s Manual Features and Benefits The DMS-OUT is loaded with features to provide the perfect audio experience. Enjoy features such as: ● 3rd Party Audio Device Integration DMS-OUT grants 3rd party devices the ability to use sources that are available in the DMS Audio Stream. ● Audio Sensing Capability The DMS-OUT, similar to the URC Audio Sensor (SEN-AUD), can detect an audio signal which can then trigger n activity (macro).
DMS-OUT Owner’s Manual Rear Panel: 5V DC Input: Provides power to the DMS-OUT. PoE may be used as a substitute. Analog Input: Standard RCA (analog) connector. Digital Input - Optical: This input uses standard S/PDIF OPTICAL TOSLINK connector. Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1 to a DMS Stream.
DMS-OUT Owner’s Manual Digital Input - Coax: Standard RCA (analog) connector, this receives bitstreams of audio data. Note: The DMS-OUT converts Dolby Digital 5.1/DTS 5.1 to a DMS Stream. LAN Port: This 10/100 Ethernet port supports PoE and sends the URC Audio stream through the local network, this is also how the DMS-OUT receives commands and sends audio.
DMS-OUT Owner’s Manual Top Panel & LED States: There are three (3) LED lights at the top of the DMS-OUT which can provide users with basic troubleshooting information. Status LED ● Off Unit has not been programmed with a Total Control file. ● Yellow Unit has been programmed with a Total Control file; however, is not creating a DMS Audio Stream. ● Blue Unit has been programmed with a Total Control file and is creating a DMS Audio Stream through the network. Power LED ● Off Unit is not receiving power.
DMS-OUT Owner’s Manual Network LED ● Off Unit is not connected to the local area network and cannot send/receive data. ● Blinking Green Unit is connected to the local network, but has not received an IP address. ● Green Unit is connected to the local network and has an IP address. Bottom Panel Located beneath the DMS-OUT is a Reset button. The Reset button is recessed so a paperclip or something similar is required to press.
DMS-OUT Owner’s Manual Wiring the DMS-OUT In order for the DMS-OUT to provide the best possible experience, it must be first wired correctly then programmed by a Total Control Certified Installer. Follow these steps to prepare the DMS–IN for programming: 1. Power the DMS-OUT with the supplied 5V DC adapter OR PoE using the LAN port (see below) OR 2. Connect and Ethernet cable from the LAN 10/100 port to an MFS-8/MFSPOE-8 ● The 5V DC adapter is not required when using PoE 3.
DMS-OUT Owner’s Manual Specifications Microprocessor: Cortex-A5 600MHz Memory: 128MB NAND, 128MB RAM Network: One 10/100 Ethernet port (PoE) Weight: 5.8oz Size: 4.6” x 4.6” x 1.
DMS-OUT Owner’s Manual Limited Warranty Statement 1. Limited Warranty and Disclaimers Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be free from defects in material and workmanship under normal usage for one (1) year from purchase when such is purchased from URC. This limited warranty is valid only in the United States of America. URC warrants that the software will substantially conform in any material respect to its functional specifications at the time of delivery.
DMS-OUT Owner’s Manual FITNESS FOR A PARTICULAR PURPOSE. URC DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF, OR THE RESULTS OF THE USE OF, THE EQUIPMENT, SOFTWARE OR DOCUMENTATION IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY OR OTHERWISE. EXCEPT AS EXPRESSLY PROVIDED FOR HEREIN, TECHNICAL SERVICES ARE SUPPLIED “AS IS”, WITHOUT ANY WARRANTY, EXPRESS, STATUTORY OR IMPLIED, OF ANY KIND.
DMS-OUT Owner’s Manual affording adequate protection to URC at 420 Columbus Avenue, Valhalla, NY 10595. It is end user’s responsibility to backup any macro programming, artwork, software or other materials that may have been programmed into the unit. It is likely that such data, software, or other materials will be lost during service and URC will not be responsible for any such damage or loss. A dated purchase receipt, bill of sale, installation contract or other verifiable proof of purchase is required.
DMS-OUT Owner’s Manual 2. URC’s Limitations of Liability IN NO EVENT SHALL URC BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL, EXEMPLARY, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND OR LOSS OF PROFITS OR BUSINESS OPPORTUNITY, EVEN IF URC IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL URC BE LIABLE FOR LOSS OF OR DAMAGE TO DATA, COMPUTER SYSTEMS OR COMPUTER PROGRAMS.
DMS-OUT Owner’s Manual End User Agreement The terms and conditions of the End User Agreement available at www.universalremote.com/eua.php shall apply. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
DMS-OUT Owner’s Manual Warning! Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Note: The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC Caution This device complies with Part 15 of the FCC Rules.
DMS-OUT Owner’s Manual Regulatory Information to the user ● CE conformity Notice Products with “CE” marking comply EMC Directive 2014/30/EU issued by the commission of the European Community. 1. EMC Directive ● Emission :EN 55032 ● Immunity :EN 55024, EN55020 ● Power :EN-61000-3-2, 3 ● Declaration of Conformity “Hereby, Universal Remote Control Inc. declares that this DMS-OUT is in compliance with the Essential requirements: Certification Type No.(Model No.) Batch/Serial No. Power Rating DMS-OUT 48.
DMS-OUT Owner’s Manual Declaration of Conformity Company Name : Universal Remote Control Inc. Company Address : Contact Information : Brand Name : 500 Mamaroneck Avenue, Harrison, NY 10528, U.S.A www.universalremote.