Owner Manual

Troubleshooting Operations
Customer Service 1•800•787•6649 37
Light issues cont.
3. Section of lights failing to operate.
a. If an entire section of lights is failing to operate first inspect that the light strand/s is properly
connected to the daisy chain.
b. If lights are properly connected but no light is being emitted, replace light strand
4. No lights working on spa.
a. If no lights operate on the spa but the topside control led for the light button is illuminating when
pressed the topside is functioning properly
b. In the spa pack there is a 3 amp fuse for the lights
c. Turn power off to spa, remove fuse, and test it for continuity
d. If fuse is good, test voltage coming from the light port on the circuit board. Should be 12v
e. The spa can have a light control box or a master light
f. If using a master light.
i. Unplug daisy chain from the master light.
ii. If master light turns on, there is a short on the daisy chain created by a light strand clip not
being properly installed.
iii. Plug in daisy chain.
iv. Unplug one light strand at a time until all the other lights turn on. This means the short has
been removed.
v. Plug other light strands back in until all lights function properly.
g. If using a light control box.
i. Unplug daisy chain from the control box.
ii. Test voltage coming out of light control box. Voltage should be 5v.
iii. If the voltage is correct, there is a short on the daisy chain created by a light strand clip not
being properly installed.
iv. Plug in daisy chain.
v. Unplug one light strand at a time until all the other lights turn on. This means the short has
been removed.
vi. Plug other light strands back in until all lights function properly.
Master Light
Light Control Box