Operate Your Spa
Topside Control Panels
System Settings
When your spa is first actuated, it will go into Prim-
ing mode, indicated by “Pr.” The Priming mode will
last for less than 5 minutes (press a Temperature
button to skip Priming Mode) and then the spa will
begin to take temperature readings, followed by the
heater test cycle. After completed, the heater will
turn on, heat the spa and maintain the water tem-
perature in the Standard mode.
The start-up temperature is set at 100°F/37°C.
The last measured temperature is constantly dis-
played on the LCD. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least 2 minutes.
Maximum Temperature is set at 104ºF/40ºC
as required by UL/CSA.
Minimum temperature is 80ºF/26ºC.
Note: If the spa is currently in a heating or filtration
cycle the primary pump will only switch between high
and low. It cannot be turned off until the heating or fil-
tration cycle is completed.
Preset Filter Cycles
The first filter cycle
begins 6 minutes after
the spa is energized.
The second filter cycle begins 12 hours later. The
default filter time is 2 hours. Recommended setting
is F2.
Example: In a 12 hour period (1 cycle), a setting of F2
means 2 hours of filtration on, 10 hours of filtration off.
You may choose F2, F4, F6, F8 or c (continuous).
To program, press the WARM/TEMP button,
immediately followed by JETS/JETS 1. Press WARM/
TEMP button to adjust. Press JETS/JETS 1 to lock in
selection. After locking in a D, N, OR DN may
appear. If so, press WARM/TEMP until DN appears,
and press JETS/JETS 1 to lock in selection.
1. Fading: The lights will cycle through all the
colors in this order: White, Cyan, Magenta, Blue,
Chartreuse, Green, Red
2. Color Locked: This cycle offers a hard color
change without fading.
3. Quick Color Change: Each time you press the
button, you advance to the next color.
4. Flashing white: The LED lights will flash white.
Spa Modes
Standard Mode is programmed to maintain the
desired temperature. Note that the last measured
spa temperature dis-played is current only when the
pump has been running for at least 2 minutes. “ST”
or "STD" will be displayed momentarily when you
switch into Standard Mode. The temperature is
constantly displayed when in Standard Mode. This is
the best mode to use during COLD weather.
(FRQRP\0RGH
heats the spa to the set
temperature only during filter cycles or if the
temperature falls to 20 degrees below set
temperature. “EC” or "ECN" will display solid when
temperature is not current, and will alternate with
the temperature, when temperature is current. This
is the best mode to use during WARM weather.
6OHHS0RGH
heats the spa to 20 degrees below set
temperature, only during filtration cycles. “SL” will
display solid when temperature is not current, and
will alternate with temperature when temperature
is current, but only within 20 degrees of your set
temperature.
Freeze Protection
If the temperature sensors detect a drop to below
44°F/6.7°C within the heater, the pumps will auto-
matically activate to provide freeze protection. The
equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to
45°F/7.2°C or higher.
Lights
Press the Light button on the topside control panel
to turn the spa light on. If your spa has perimeter
LED lights, they will also light up at the same time as
the spa light. LEDs operate in four modes. The mode
is changed by turning the light off and then immedi-
ately back on