Operation Manual
59
OCS OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5272-r01 (9/28/11)
CAN BE USED AS
•  Watch
•  Dive Computer (Air or Nitrox) 
•  Digital Depth Gauge/Timer
•  Free Dive activity
•  Compass
DIVE COMPUTER PERFORMANCE
•  Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm
•  No Deco limits closely follow PADI RDP
•  Decompression in agreement with Buhlmann ZHL-16c and French MN90
•  No Deco Deep Stops - Morroni, Bennett
•  Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
•  Altitude - Buhlmann, IANTD, RDP (Cross)
•  Altitude corrections and O2 limits based on NOAA tables 
OPERATIONAL PERFORMANCE
Function:  Accuracy:
•  Depth  ±1% of full scale
•  Timers  1 second per day
Dive Mode Activation:
• Must be in Dive Computer mode, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 5 FT (1.5 M), if Water Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters) 
Dive Counter:
•  NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet) 
•  Resets to Dive #1, upon diving (after 24 hours with no dives)
Dive Log Mode:
•  Stores 24 most recent NORM/GAUG dives in memory for viewing
•  After 24 dives, adds 25th dive in memory and deletes the older dive
Altitude:
•  Operational from sea level to 14,000 feet (4,270 meters) elevation
•  Measures ambient pressure every 30 minutes in Watch Mode, when Dive Computer Mode is accessed, and every 15 minutes while in NORM/GAUG/FREE Surface Modes.
•  Does not measure ambient pressure when Wet.
•  Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
• Battery  (1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent)
• Shelf life  Up to 7 years (when shipped from factory in Deep Sleep mode)
• Replacement  User replaceable (annual recommended)
• Use Life  1 year or 300 dive hours if (2) 1 hour dives per dive day
Battery Icon: 
•  Warning >> icon on solid when <= 2.75 volts, Battery change recommended
•  Alarm >> icon on flashing when <= 2.50 volts, change the Battery, will not function as a DC 
Operating Temperature:
•  Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
•  In storage case provided >> between 14 °F and 158 °F (-8 and 70 °C).
•  In the water >> between 28 °F and 95 °F (-2 and 35 °C). 
BAR GRAPHS 
TLBG    segments      O2BG        segments
• No Deco Normal zone    3          • Normal zone    3 
• No Deco Caution zone    1          • Caution zone    1 
• Decompression zone    1          • Danger zone    1 
VARI  60 FT (18 M) & Shallower        Deeper than 60 FT (18 M) 
    segments    FPM    MPM      segments      FPM    MPM
      0      0 - 10  0 - 3        0        0 - 20  0 - 6 
•  Normal Zone    1      11 - 25  3.5 - 7.5    1        21 - 50  6.5 - 15
•  Caution Zone    2      26 - 30  8 - 9        2        51 - 60  15.5 - 18
•  Too Fast Zone (flashing)    3 (all)    > 30    > 9        3 (all)     > 60    > 18
SPECIFICATIONS