Operation Manual

29
OCS OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5272-r01 (9/28/11)
Fig. 67 - NO DECO MAIN
NO DECO MAIN, information includes (Fig. 67) -
> Current Depth with FT (or M) icon, *
or dashes during the first 10 minutes on the surface.
> DTR (hr:min) with graphic NDC (or OTR), whichever is less at the time, *
or dashes during the first 10 minutes on the surface
.
> *
Surface Interval Time (hr:min) with graphic SURF and time (clock) icon during the first 10 minutes on the surface
.
> Graphic GAS1 (or 2 or 3), one in use.
> Nx icon, if any Gas is set for Nitrox.
> TLBG with NI icon.
> VARI while ascending.
*The Dive Main continues to be displayed during the first 10 minutes after surfacing with
access to Dive ALTs.
• A (< 2 sec) to access ALTs.
• A (2 sec) to access Deep Stop Preview**, if triggered.
• M (< 2 sec) to access Gas Switching**.
• S (< 2 sec) to acknowledge alarms.
• S (2 sec) to access Compass**.
• L (press) to activate Backlight.
**These items can only be accessed while viewing the Main.
No Deco Alt 1, information includes (Fig. 68) -
> Max Depth with FT (or M) and MAX icons.
> Elapsed Dive Time (hr:min) with graphic EDT.
> FO2 Set Point for Gas in use with graphic FO2.
> Current PO2 value (ATA) with graphic, if Nitrox.
> Nx icon, if Nitrox.
> O2BG with O2 icon, if Nitrox.
• A (< 2 sec) - to access ALT 2.
• Revert to Main in 5 sec, if A not pressed.
No Deco Alt 2, information includes (Fig. 69) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• 5 sec or A (< 2 sec), revert to Main.
Deep Stop Preview, information includes (Fig. 70) -
> Stop Depth with graphic FT (or M) and countdown Time as 2:00 (min:sec).
> Graphic DEEP STOP.
• 5 sec, revert to No Deco Main.
• L (press) - to activate Backlight.
DEEP STOP MAIN, information includes (Fig. 71) -
> Current Depth with FT (or M) icon.
> Stop Depth with graphic FT (or M) and remaining countdown Time (min:sec).
> Graphic GAS1 (or 2 or 3), one in use.
> Nx icon, if any Gas is Nitrox.
> TLBG with NI icon.
• A (< 2 sec) - to access ALTs.
• M (< 2 sec) - to access Gas Switching.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access Compass.
• L (press) - to activate Backlight.
Deep Stop Alt 1, information includes (Fig. 72) -
> Max Depth with MAX and FT (or M) icon.
> DTR (hr:min) with graphic NDC (or OTR if less).
> Elapsed Dive Time (hr:min) with graphic EDT.
> FO2 Set Point for Gas in use with graphic FO2.
> Current PO2 value (ATA) with graphic, if Nitrox.
> Nx icon, if Nitrox.
> O2BG with O2 icon, if Nitrox.
• A (< 2 sec) - to access ALT 2.
• Revert to Main in 5 sec, if A not pressed.
Deep Stop Alt 2, information includes (Fig. 73) -
> Time of Day (hr:min sec), with A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
• 5 sec or A (< 2 sec), revert to Main.
Fig. 68 - NO DECO ALT 1
Fig. 69 - NO DECO ALT 2
Fig. 70 - DEEP STOP
PREVIEW
Fig. 71 - DEEP STOP MAIN
Fig. 72 - DEEP STOP ALT 1
Fig. 73 - DEEP STOP ALT 2