Operation Manual
22
OCS OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5272-r01 (9/28/11)
• A (hold) - to scroll upward through Set Points at a rate of 8 per sec from 0:10 to 3:00 (hr:min) in increments of 0:05 (:min). 
• A (< 2 sec) - to step upward through Set Points one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and revert to the Set A Menu.
FREE Mode has a separate EDT Alarm.
Set TLBG Alarm, information includes (Fig. 43, page 21):
> Graphic TLBG AL.
> Depth value flashing with MAX and FT (or M) icons. 
• A (< 2 sec) - to step upward through Set Points from 1 to 4 segments one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and revert to the Set A Menu.
FREE Mode has a separate TLBG Alarm.
Set DTR Alarm, information includes (Fig. 44, page 21):
> Graphic DTR AL.
> Dive Time Remaining value (hr:min) flashing with Time (clock) icon. 
• A (hold) to scroll upward through Set Points at a rate of 8 per sec from 0:00 to 0:20 (hr:min) in increments of 0:01 (:min). 
• A (< 2 sec) - to step upward through Set Points one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and revert to the Set A Menu.
SET U (UTILITIES) MENU  
• S (< 2 sec) - to access Set U Menu while the selection Arrow icon ( > ) is next to Set U on the NORM (or GAUG) Menu.
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
Selections for Wet Activation, Units, Algorithm, Conservative Factor, and Glo Duration also apply to FREE Dive Mode. 
> To change any of these items while in FREE mode, use the Set U selection in the NORM Menu.
Set Wet Activation, information includes (Fig. 45):
> Graphic WET ACTIV.
> Set Point graphics ON and OFF, Arrow ( > ) icon next to the one previously saved flashing.
• A (< 2 sec) - to toggle Set Points. 
• S (< 2 sec) - to save the setting and revert to the Set U Menu.
Set Units, information includes (Fig. 46):
> Graphic UNITS.
> Set Point graphics IMPERIAL and METRIC, Arrow ( > ) icon next to the one previously saved flashing.
• A (< 2 sec) - to toggle Set Points. 
• S (< 2 sec) - to save the setting and revert to the Set U Menu.
Set Deep Stop, information includes (Fig. 47):
> Graphic DEEP STOP.
> Set Point graphics ON and OFF, Arrow ( > ) icon next to the one previously saved flashing.
• A (< 2 sec) - to toggle Set Points. 
• S (< 2 sec) - to save the setting and revert to the Set U Menu.
Deep Stop applies only to NORM No Deco dives. 
Set Safety Stop, information includes (Fig. 48A):
> Graphics SS (= Safety Stop). 
> Set Point graphics OFF, ON, TMR ON; Arrow ( > ) icon next to ON or OFF, the one previously saved, flashing.
• A (< 2 sec) - to step forward through Set Points one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting.
> 
If OFF or TMR ON is selected/saved, operation will revert to the Set U Menu.
> 
If ON is selected/saved, the Set Stop Time/Depth screen is displayed with the Time digits flashing (Fig. 48B).
• A or M (< 2 sec) - to toggle between 3:00 and 5:00 (min:sec).
• S (< 2 sec) - to save the Time setting and flash the Depth digits.
• A (< 2 sec) to step forward through Depth Set Points of 10, 15, 20 FT (or 3, 4, 5, 6 M).
• M (< 2 sec) to step back through Set Points one at a time.
• S (< 2 sec) to save the SS Time/Depth setting and revert to the Set U Menu.
Safety Stop applies only to NORM No Deco dives. 
Set Algorithm, information includes (Fig. 49):
> Graphic ALGORITHM.
> Set Point graphics Z+ and DSAT, Arrow ( > ) icon next to the one previously saved flashing.
** NORM only
Fig. 45 - SET WET ACTIV
Fig. 46 - SET UNITS
Fig. 47 - SET DEEP STOP
Fig. 48B - SET SAFETY STOP 
(TIME & DEPTH)
Fig. 48A - SET SAFETY STOP 
(TIMER)
Fig. 49 - SET ALGORITHM