Operation Manual
11
DataTrans Plus
ented (U.S. Patent No. 4,586,136) breathing gas consumption calculation
method makes information accurate even during sudden changes in depth.
Breathing Gas Time Remaining Bar Graph
The Breathing Gas Time Remaining Bar Graph located along the bottom of
the display (Fig. 11) provides a graphic representation of the time that you can
remain at your present depth and then, following a safe ascent, surface with a
predetermined breathing gas reserve. This calculation and display is based on
your breathing gas consumption rate that is continually monitored by the
DataTrans Plus, and it takes into account the breathing gas required for a safe
ascent including any required decompression stops.
The green, yellow, and red zones adjacent to the bar graph enable you to
quickly focus on remaining breathing gas times of 60 minutes or less, based on
your pre selected Gas Alarm Set Point. The bar graph is more precise as time
remaining decreases toward the red zone.
DIVE TIME REMAINING
One of the most important pieces of information on the DataTrans Plus is the
patented Dive Time Remaining numeric display. To numerically display Dive
Time Remaining, the DataTrans Plus constantly monitors three critical pieces
of information; no decompression status, oxygen accumulation status, and rate
Fig. 11 - Breathing Gas
Time Remaining Bar Graph
®
DECO
C.Z. C.Z.
O
2
NO DECO
0
5
10
20
30
40
50
60