Operation Manual
116
®
Power (Display & Transmitter)
• Battery Each - 1 - 3.6 v, 1/2AA, TADIRAN
®
Lithium
Model TL-2150
• Shelf life Up to 10 years
• Replacement User replaceable (annual recommended)
• Life expectancy 100 dives, or 1 year, whichever comes first
NOTE: Battery life is maximized when batteries are removed from
the DataTrans Plus Transmitter and Display Unit during periods of
inactivity that exceed 1 week.
Activation:
• Display Module - manual push button
• Transmitter - gas pressure
• Cannot be activated by water immersion
• Cannot be activated deeper than 4 feet (1.5 m)
• Cannot be activated at elevations higher than 14,000 feet (4,267 m)
• Needed before first dive, and after a 12 hour surface interval.
• Automatically shuts unit off if dive is made within 120 minutes after
initial activation. Reactivation required.
• Cannot be shut off manually.
Special Displays
Occurrence
• Audible Alarm Access On demand
• Diagnostic Display Activation
• Out of Range >330 feet (>99.5 meters)
• Gauge Mode Countdown Timer 12 – 24 hours (after violation)
OPERATIONAL PERFORMANCE
Function
Accuracy
• Depth ± 1% of full scale
• Cylinder Pressure ± 1% of full scale
• Timers 1 second per day
Dive Counter
• Displays Dives #1 - #9then recycles to #1 (continues to #9)
• Resets to Dive #1, upon diving (after 12 hour surface time)
Dive Log Mode
• Stores 12 most recent dives in memory for viewing
• After 12 dives, adds 13th dive in memory and deletes the first dive
Altitude
• Operational from sea level to 14,000 feet (4,267 meters) elevation
• Recalibration of depth readings from 'feet of sea water' to 'feet of fresh water'
when higher than 2,000 feet (610 meters) elevation
SPECIFICATIONS (continued)