Operation Manual

116
®
Power (Display & Transmitter)
• Battery Each - 1 - 3.6 v, 1/2AA, TADIRAN
®
Lithium
Model TL-2150
• Shelf life Up to 10 years
• Replacement User replaceable (annual recommended)
• Life expectancy 100 dives, or 1 year, whichever comes first
NOTE: Battery life is maximized when batteries are removed from
the DataTrans Plus Transmitter and Display Unit during periods of
inactivity that exceed 1 week.
Activation:
Display Module - manual push button
Transmitter - gas pressure
Cannot be activated by water immersion
Cannot be activated deeper than 4 feet (1.5 m)
Cannot be activated at elevations higher than 14,000 feet (4,267 m)
Needed before first dive, and after a 12 hour surface interval.
Automatically shuts unit off if dive is made within 120 minutes after
initial activation. Reactivation required.
Cannot be shut off manually.
Special Displays
Occurrence
Audible Alarm Access On demand
Diagnostic Display Activation
Out of Range >330 feet (>99.5 meters)
Gauge Mode Countdown Timer 12 – 24 hours (after violation)
OPERATIONAL PERFORMANCE
Function
Accuracy
Depth ± 1% of full scale
Cylinder Pressure ± 1% of full scale
Timers 1 second per day
Dive Counter
Displays Dives #1 - #9then recycles to #1 (continues to #9)
Resets to Dive #1, upon diving (after 12 hour surface time)
Dive Log Mode
Stores 12 most recent dives in memory for viewing
After 12 dives, adds 13th dive in memory and deletes the first dive
Altitude
• Operational from sea level to 14,000 feet (4,267 meters) elevation
• Recalibration of depth readings from 'feet of sea water' to 'feet of fresh water'
when higher than 2,000 feet (610 meters) elevation
SPECIFICATIONS (continued)