Operation Manual
115
DataTrans Plus
SPECIFICATIONS (continued)
Oxygen Accumulation (O2) Bar Graph
segments
Normal zone (green) 12
Caution zone (yellow) 3
Danger zone (red) 1
Breathing Gas Time Remaining Bar Graph
segments
Normal zone (green) 28
Caution zone (yellow) 2
Danger zone (red) 5
Variable Ascent Rate Indicator (VARI)
segments feet/min. meters/min.
none 0 - 10 0 - 3
Normal zone (green) 1 11 - 20 3 - 6
2 21 - 30 6 - 9
3 31 - 40 9 - 12
Caution zone (yellow) 4 41 - 50 12 - 15
5 51 - 60 15 - 18
Too Fast zone (red flashing) 6 61 - 90 18 - 27
7 91 - 120 27 - 36
8 >120 >36
Breathing Gas Consumption Indicator
segments
Normal zone (green) 3
Caution zone (yellow) 2
High zone (red) 3
DISPLAY RANGE/RESOLUTION
Numeric Displays:
Range: Resolution:
• Dive Number 0 - 9 1
• Depth 0 - 330 ft (0 - 99.5 m) 1 ft (.5 m)
• Maximum Depth 330 ft (99.5 m) 1 ft (.5 m)
• FO2 Set Point 21 - 50 % 1 %
• PO2 Value 1.40 - 5.00 ATA .01 ATA
• Gas Time Remaining 0 - 9 hr. 59 min. 1 minute
• No Decompression Time 0 - 9 hr. 59 min. 1 minute
• Decompression Time 0 - 9 hr. 59 min. 1 minute
• Elapsed Dive Time 0 - 99 min. 1 minute
• Surface Time 0 - 11 hr. 59 min. 1 minute
• Dive Log Surface Interval 0 - 11 hr. 59 min. 1 minute
• Time to Fly 23 hr. 50 min. - 0* 1 minute
(* starting 10 min. after the dive)
• Cylinder Pressure 0 - 8190 psi 10 psi
(0 - 564 BAR) (.5 BAR)
GRAPHIC DIVER INTERFACE
Tissue Loading Bar Graph
segments
No Decompression zone (green) 12
No Deco Caution zone (yellow) 3
Decompression Warning zone (red) 1
R2