Operation Manual

104
®
Transmitterss that have been specifically prepared for Oxygen Ser-
vice by the Oceanic factory, as identified to be Oxygen Clean and
Oxygen Compatible by a special tag affixed to it, can be used with
any nitrogen-oxygen (Nitrox) breathing gas mixture to a maximum of
100 (%) Oxygen.
If a Transmitter prepared by the Oceanic factory, and certified and
tagged for Oxygen Service, is subsequently used with compressed air,
it cannot then be used with nitrogen-oxygen (Nitrox) breathing gas
mixtures in which the percentage of oxygen (O2) in the Nitrox will be
greater than 50 (%).
Only the Oceanic factory can prepare Oceanic DataTrans Plus Trans-
mitters for use with nitrogen-oxygen (Nitrox) breathing gas mixtures
in which the percentage of oxygen (O2) in the Nitrox will be greater
than 50 (%).
Responsible