Operation Manual

101
DataTrans Plus
above the threads.
• Insert the spring into the cap with the large end first (small end facing
out), and insert the battery into the housing (Fig. 110). For the Trans-
mitter, the positive (+) end of the battery goes into the housing first with
the negative (-) end toward the cap. For the Display Module, the negative
(-) end of the battery goes into the housing first with the positive (+) end
toward the cap.
• Carefully insert the battery cap into the housing and turn clockwise by
hand until snug. To ensure correct threading and overcome spring pres-
sure apply slight inward pressure as you begin turning the cap. Apply a
coin to the recessed slot and tighten until secure.
• Activate the Display Module and watch carefully as it performs a full diag-
nostic and battery check, and signal link with the Transmitter.
• Examine the LCD display to ensure it is consistently clear and sharp in
contrast throughout the screen.
FLOODED BATTERY COMPARTMENT
Note: For any cause of flooding other than a bad o-ring, return
the complete DataTrans Plus for factory service.
If moisture is found in the battery compartment, it is best to have your
DataTrans Plus inspected and cleaned by an Authorized Oceanic Dealer.
Fig. 110 - Battery
Installation
Housing
Battery
1/2AA
3.6 v
( - )
( + )
Transmitter
+
( - )
( + )
Battery
1/2AA
3.6 v
Housing
Spring
Battery
Cap
Display Module
-
+
Battery
Cap
-
Spring