Operation Manual

100
®
WARNING: Damage due to improper battery replacement is
not covered by the DataTrans Plus limited 2 year warranty.
Follow directions exactly.
• Apply a coin (not a screwdriver) to the recessed slot of the battery cap,
and turn the cap out counterclockwise to remove it from the housing.
Note: The battery compartment should only be opened in a dry and clean
environment, with extreme care taken to prevent the entrance of mois-
ture or dust.
• Remove the battery from the cap using care not to lose the spring located
behind the battery. Closely examine the spring and contact area inside
the battery compartment for any signs of corrosion indicating entrance of
moisture into the unit. If found, return your DataTrans Plus to an Au-
thorized Oceanic Dealer, and DO NOT use it until it has received service.
• To remove the o-ring, press the sides with your fingertips to cause it to
protrude slightly from the groove of the cap and lift it over the head of
the cap. DO NOT use tools to remove.
• Closely check the threads of the battery cap and the housing for any signs
of damage which might impair proper threading. If found, return your
DataTrans Plus to your Authorized Oceanic Dealer, and DO NOT at-
tempt to use until it has received factory service.
To replace the o-ring, lightly lubricate it with silicon grease and stretch it
slightly to work it down over the head of the cap (Fig. 109), DO NOT roll
it over the threads. Ensure that it is evenly seated inside the groove
Fig. 109 - O-ring
Installation
Battery
Cap
O-ring