4. LOADING THE EPIRB1 PRO
! When replacing the EPIRB1 Pro in the Float Free Housing please ensure that the
unit is clean and dry. The area around the activation controls and the lanyard
should be free from water and dirt to ensure reliable operation.
The EPIRB1 Pro is held in place inside the Float Free Housing by the Hydrostatic Release
Unit (HRU) which locks into position using a spring.
If it is necessary to replace the EPIRB1 Pro into the Float Free Housing (after maintenance
or testing etc):
1. Pull back the HRU
2. Load the EPIRB1 Pro, controls facing up, into the location seat, ensuring to
carefully fold the antenna back behind the EPIRB1 Pro.
3. Gently lower the HRU back into the locked position - this holds the EPIRB1
Pro securely in place.