2) Push the HRU down, against the spring and remove the locking pin,
carefully remove the HRU from the spring.
3) With the new HRU locate the two retaining ridges (at the bottom of
the HRU) on to the spring.
4) Carefully push down on the HRU, against the spring. Have the
locking pin ready, with the retaining flange (the flat surface) pointing
down.
5) Push the locking pin fully home, the HRU is now ready to load the
EPIRB into the housing.
6.6: Service & Warranty
All servicing or repairs of this EPIRB must be carried out by an approved
service agent.
For warranty details please refer to the warranty card supplied with this unit.
Please retain the original packaging for your EPIRB. If the EPIRB has to be
returned, for any reason, the original packaging should be used.