Optical Multiplexer MPM-2000 Installation and Operation Manual Document Number 000-10000-120-02-1209 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.2447 Fax 727.733.3962 8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST Ocean Optics Mikropack Maybachstraße 11, D-73760, Ostfildern, Germany Phone +49 (0)711 34 16 96-0 Fax +49 (0)711 34 16 96-85 E-mail: Info@OceanOptics.com Info@Mikropack.de Orders@OceanOptics.com TechSupport@OceanOptics.
Copyright © 2009 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without the prior consent of Ocean Optics, Inc.
Important Safety Notices 1. Read all safety notices and operating instructions before operating this unit. 2. Inspect the item for transport damage before using the 24VDC power supply for the first time. 3. Adhere to all warning stickers on the unit and all warnings contained in this manual.
Important Safety Notices 3. Send the equipment to the local distributor for repair. If the item is under warranty, shipping will be free-of-charge both ways. 4. Contact your distributor for repair and delivery time. If the item is out of warranty, your distributor will provide a repair cost to you. In this situation, the distributor will not proceed with the repair until you order it. Your system will be shipped back to you free of charge with insurance (if under warranty).
Table of Contents About This Manual .............................................................................................................iii Document Purpose and Intended Audience.............................................................................. iii What’s New in this Document ................................................................................................... iii Document Summary..............................................................................................
Table of Contents Syntax.................................................................................................................................20 Operating/Interfacing with the Optical Multiplexer.............................................................21 Calibrating the MPM-2000 .................................................................................................22 Index ......................................................................................................
About This Manual Document Purpose and Intended Audience This document provides you with an installation section to get your system up and running. What’s New in this Document This version of the Optical Multiplexer MPM-2000 Installation and Operation Manual removes calibration information. Document Summary Chapter Description Chapter 1: Setup Contains a list of package contents and unpacking instructions.
About This Manual Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. Please contact an Ocean Optics Application Scientist for specific instructions when returning a product.
Chapter 1 Setup Overview The MPM-2000 Fiber Optic Multiplexer is a compact instrument that can optically couple one input channel to 16 different output channels. The MPM-2000 consists of a precisely controlled DC-motor with encoder and end switch on a rotator block. The optical path couples via UV collimating lenses. The Multiplexer features a CNC controller working in positioning mode, which eliminates step loss. The MPM-2000 is software controlled and interfaces to a PC through the RS-232 protocol.
1: Setup Unpacking the MPM-2000 ► Procedure 1. Unpack the Optical Multiplexer carefully. Dropping this instrument can cause permanent damage. 2. Inspect the outside of the instrument and make sure that there is no damage. Do not use the instrument if damage is present. Contact your dealer for repair or replacement information, if necessary. 3. Use this instrument in a clean laboratory environment. 4. Submit the Registration Card to for warranty and support purposes.
1: Setup Typical System Configuration 000-10000-120-1209 3
1: Setup 4 000-10000-120-02-1209
Chapter 2 MPM-2000 Specifications This section provides information on the operating environment and physical controls of the MPM-2000. Operating Environment The following table provides information on optimizing the operating environment of your MPM-2000. Operating Environment The MPM-2000 Unit . . . Moisture Is designed for operation in dry rooms only. Ventilation Should be situated so that its location or position does not interfere with proper ventilation.
2: MPM-2000 Specifications MPM-2000 Components The following sections describe the components located on the front and rear of the MPM-2000 unit. Front Panel SMA 905 Connectors Power LED Error LED Note The front panel of both the 1 x 16 and 2 x 8 versions of the MPM-2000 are identical. Only the rear panel will differ (two inputs on the 2 x 8 version).
2: MPM-2000 Specifications Rear Panel Type Sign SMA 905 Connector (connects to spectrometer) RS232 Port Connection (connects to PC) 24 VDC Power Input 000-10000-120-1209 7
2: MPM-2000 Specifications 8 000-10000-120-02-1209
Chapter 3 Operating Instructions Operating Software The MPM-2000 comes with easy-to-use Windows-based software that allows you to control the MPM2000 Optical Multiplexer manually or create sequence programs (scripts) with preconfigured channel settings and delay times.
3: Operating Instructions Channel Mode Channel Mode allows you to change the active channel on the MPM-2000. You can click on any of the blue buttons associated with the SMA 905 Connectors on the front of the MPM-2000 to activate that channel. Once you activate a channel, the button for that channel turns red until you activate another channel.
3: Operating Instructions Program Mode Program Mode allows you to create or change sequence programs used by the MPM-2000.
3: Operating Instructions Small Mode Small Mode provides all functionality of the software in a condensed menu bar. When using another software package, the Always on Top feature of Small Mode eliminates the need to consistently switch back and forth between applications. This mode is only accessible via the View Menu.
3: Operating Instructions Main Toolbar The Main Toolbar is only visible in Channel Mode and Program Mode.
3: Operating Instructions View Menu The View Menu allows you to toggle between the three different application modes. You can only access Small Mode using this option. Tools Menu The Tools Menu contains the following options: Menu Option Description Connect Connects to the MPM-2000 Disconnect Disconnects from the MPM-2000 Options Opens the Options dialog box Options Dialog Box The Options dialog box is accessible from the File Menu or Tools Menu.
3: Operating Instructions Settings Tab Click the Always On Top check box to position the software window above any other running applications, and then click the OK button to save your changes. To specify the default mode that the MPM-2000 software will enter upon startup, select one of the three radio button options under the Startup View section of the Settings tab, and then click the OK button. MPM-2000.drv The MPM-2000.DRV is an interface DLL for use with Visual Basic or C/C++.
3: Operating Instructions 16 000-10000-120-02-1209
Appendix A RS232 ASCII Commands Program File The MPM-2000 Optical Multiplexer is interfaced via the RS232 protocol.
A: RS232 ASCII Commands Line Command 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 answ0 jmp1 SWVersion100 SN03918XXXX Ch01-400 Ch02-100 Ch03200 Ch04500 Ch05800 Ch061100 Ch071400 Ch081700 Ch092000 Ch102300 Ch112700 Ch123000 Ch133300 Ch143600 Ch153900 Ch164200 A1 v-60 delay800 gohix delay50 la-400 m delay10 27 28 18 // asynchronous answers deactivated // version of the windows-software // serialnumber of the multiplexer // absolute position of channel 1: -400 // absolute positio
A: RS232 ASCII Commands New Data Format Line 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 000-10000-120-1209 Command answ 0 jmp 1 la 200 la 39180030 la -1095 la -188 la 711 la 1611 la 2516 la 3412 la 4312 la 5209 la 6104 la 6996 la 7887 la 8799 la 9700 la 10600 la 11508 la 12404 a1 v -70 delay 600 gohix delay 50 la -1095 m delay 50 19
A: RS232 ASCII Commands Syntax Every command sent via RS232 to the MPM-2000 consists of the following parts: Command sequence, Parameter (if needed), Carriage Return [CR] To set an absolute position you need to send: LA1000[CR] // Load absolute position 1000 M[CR] // initiate motion Command Description Example M Initiate Motion (Move) M[CR] LA Load absolute target position LA1000[CR] Allows programming of the desired target position relative to the present zero or "home" position.
A: RS232 ASCII Commands Command Description Example GFS Get Fault Status GFS[CR] This command returns the fault status Bit Description ANSW 0 Over-temperature condition 1 Over-current condition 2 Under-voltage (<10VDC) 3 Over-voltage (>32VDC) Asynchronous answer ON / OFF ANSW0[CR] ANSW1 activated ANSW0 deactivated GPROGSEQ This command returns the complete program sequence stored in the EEPROM GPROGSEQ[CR] Operating/Interfacing with the Optical Multiplexer The software needs to execute
A: RS232 ASCII Commands To check if the MPM-2000 has reached the given position you can poll the actual position (POS[CR]) and compare it with desired position. Note: A difference of +/-1 between the desired position and the real position can occur. This is not a functional error. Calibrating the MPM-2000 To calibrate the MPM-2000 Optical Multiplexer, you must write the complete program file to the EEPROM in the MPM-2000.
Index A Acquisition Parameter Options, 17 ASCII commands, 21 C Channel Mode, 10 components, 6 front panel, 6 rear panel, 7 Comport Options, 18 Comport Tab, 14 configuration typical system, 3 O operating environment, 5 operating instructions, 9 options Acquisition Parameter, 17 Comport, 18 Options Dialog Box, 14 P D document audience, iii purpose, iii summary, iii package contents, 2 product-related documentation, iii program file, 21 syntax, 24 Program Mode, 11 R RS232, 21 F File Menu, 13 I S Setti