2020.1

Table Of Contents
l Re-run the OL Connect Send printer driver setup on client system and select the Repair
option to point the clients to the new Server URL.
Configuring the Connect Engines
Any changes made to the Server preferences require the OLConnect_Server service to be
restarted to take effect.
1.
Stop the OLConnect_Server service from Control Panel > Administrative Tools >
Services > OLConnect_Server > Stop.
2. Configure the Merge and Weaver Engines scheduling preferences as in the previous
installation
l Open the Server Configuration from:
C:\Program Files\Objectif Lune\OL Connect\Connect Server
Configuration\ServerConfig.exe
l Configure the DataMapper, Merge and Weaver engines preferences (see "Parallel
Processing preferences" on page86). As of version 2018.1 these preferences
include the minimum (Xms) and maximum (Xmx) memory utilization for the Merge
and Weaver engines .
l Configure any other options for the Clean-up Service.
3. If the version used on the new machine is 1.8/8.8 or older, you may have to manually
configure the minimum (Xms) and maximum (Xmx) memory utilization for the Merge and
Weaver engines as previously or better.
l Edit the Xms (minimum RAM size) and Xmx (maximum RAM size) fields in the
following configuration files:
l
C:\Program Files\Objectif Lune\OL Connect\Connect Merge
Engine\MergeEngine.ini
l
C:\Program Files\Objectif Lune\OL Connect\Connect
Weaver Engine\WeaverEngine.ini
4.
Now start the OLConnect_Server service
Configuring the Server Extensions
In the case where the OLConnect MySQL is installed on the new Master Server, it is important
to reconnect all Server Extension systems to the new Master Server.
Perform the following action on each Server Extension:
Page 53