2018.1

Table Of Contents
At 0, the font size must be exactly the same between two fragments. At 1, a greater variance in
font size is accepted.
Accepted values range from 0 to 1. The default value is 0.65, recommended values are
between 0.60 and 1.00.
Gap
Defines how spaces between two fragments are processed. If the space between two
fragments is too small, the text extraction will sometimes eliminate that space and count the two
fragments as a single word. To resolve this, the Gap setting can be changed. The lower this
value, the higher the chance of a space being added between two characters. A value too low
may add spaces where they do not belong.
Accepted values range from 0 to 0.5. The default value is 0.3, recommended values are
between 0.25 and 0.40.
General and logging preferences
General plugin preferences control the level of detail added to the PReS Workflow log file.
Since log files cover 24 hours of operation, choosing to log every task performed by PReS
Workflow may result in the creation of excessively large files.
Changing the plugin preferences also affects the logs displayed in the PReS Workflow Service
Console.
l
Log level group
l
Startup and shutdown: Select to only track when the PReS Workflow service is
started and stopped.
l
Task failure: Select to only track when tasks in the processes running in a PReS
Workflow configuration fail.
l
Task success and failure with details: Select to track when the tasks in processes
running in PReS Workflow succeed and fail, with details. Details can include why
tasks fail and how successful tasks are executed.
l
All events with details: Select to log everything that happens in PReS Workflow.
This includes when it starts and stops, the success and failure of tasks, and details
on the success and failure of tasks.
Page 655