2018.1
Table Of Contents
- Table of Contents
- Welcome to PReS Workflow 2018.1
- Installation and setup
- Basics
- Features
- About Workflow Configurations
- Workflow Configuration resource files
- About data
- Data Repository
- Debugging and error handling
- About printing
- OL Connect print jobs
- PlanetPress Suite print jobs
- PReS Workflow printer queues
- Shared printer queue properties
- Windows Output printer queue
- LPR Output Printer Queue
- FTP Output Printer Queue
- Send to Folder printer queue
- Triggers
- Load balancing
- Objectif Lune Printer Driver (PS)
- Associating PlanetPress Design documents and PReS printer queues
- About processes and subprocesses
- Using Scripts
- Special workflow types
- About Tasks
- About variables
- Workflow add-ons
- About related programs and services
- The Interface
- Customizing the Workspace
- PReS Workflow Button
- Configuration Components pane
- Components Area Sections
- Process properties
- PlanetPress Design document properties
- Using the Clipboard and Drag & Drop
- Renaming objects in the Configuration Components Pane
- Reordering objects in the Configuration Components pane
- Grouping Configuration Components
- Expanding and collapsing categories and groups in the Configuration Component...
- Delete objects and groups from the Configuration Components pane
- Other Dialogs
- The Debug Information pane
- The Message Area Pane
- The Object Inspector Pane
- The Plug-in Bar
- Preferences
- Other Preferences and Settings
- General appearance preferences
- Object Inspector appearance preferences
- Configuration Components Pane appearance preferences
- Default Configuration behavior preferences
- Notification Messages behavior preferences
- Sample Data behavior preferences
- Network behavior preferences
- PlanetPress Capture preferences
- OL Connect preferences
- PDF text extraction tolerance factors
- General and logging preferences
- Messenger plugin preferences
- HTTP Server Input 1 plugin preferences
- HTTP Server Input 2 plugin preferences
- LPD Input plugin preferences
- Serial Input plugin preferences
- Telnet Input plugin preferences
- PReS Fax plugin preferences
- FTP Output Service preferences
- PReS Image preferences
- LPR Output preferences
- PrintShop Web Connect Service preferences
- Editor Options
- The Process area
- Zoom in or out within Process Area
- Adding Branches
- Replacing tasks, conditions or branches
- Removing tasks or branches
- Task Properties dialog
- Cutting, copying and pasting tasks and branches
- Moving a task or branch using drag-and-drop
- Disabling tasks and branches
- Resize rows and columns of the Process Area
- Selecting a resource file in task properties
- Highlight a task or branch
- Undo a command
- Redo a command
- The Quick Access Toolbar
- The PReS Workflow Ribbon
- The Task Comments Pane
- Additional Information
- Copyright Information
- Legal Notices and Acknowledgments
Every Workflow process has its own data emulation setting, which depends on the sample data
file you choose.
A process's data emulation is only visible in the Workflow configuration tool when using the
Data Selector e.g. to select a sample data file, but it is always set to one.
A process's emulation can be changed either by choosing another sample data file (see
"Choosing a sample data file" on page63) or by inserting a "Change Emulation" on page264
task in the process.
Changing the emulation is particularly important if you want to make a data selection in a file
after it has been changed to another format (see "Data selections" on page47).
Note
Even during debugging, selecting a sample data file with a different format will cause the emulation
of a process to change. In order to avoid errors, change the emulation back to the format of the
original input file before using the process again.
Stabilizing data
All emulations, except the database, PDF and XML emulations, let you perform operations on
the data to stabilize it. The following options are available in both the "Change Emulation" on
page264 task and "The Data Selector" on page610.
Add/remove characters: Enter the number of characters to add to, or remove from, the head of
the data stream, or use the spin buttons to increment or decrement the value. Positive values
add characters; negative values remove characters. This is useful when one or more characters
of input data precede the start of the first data page. Note that certain control characters can be
problematic. For example, the NUL character (hexadecimal 00) cannot be removed from the
head of the data stream, and a backspace (hexadecimal 08) can cause unpredictable behavior.
The Hex Viewer can be useful in helping determine the control characters that appear at the
head of the data stream. (To open the Hex Viewer, select Debug > View as Hex, in the menu.)
Note that you cannot add characters in a CSV. Further note that if you remove characters in a
CSV emulation, you should ensure that you do not inadvertently remove field or text delimiters.
Add/remove lines: Enter the number of lines to add to, or remove from, the head of the data
stream, or use the spin buttons to increment or decrement the value. Positive values add lines;
negative values remove lines. This is useful when one or more lines of input data precede the
start of the first data page. Note that you cannot add lines in either a CSV or user defined
emulation.