8.7
Table Of Contents
- Table of Contents
- Welcome to PlanetPress Workflow 8.7.1
- System Requirements
- Basics
- Features
- The Nature of PlanetPress Workflow
- About Branches and Conditions
- Configuration Components
- Connect Resources
- About Data
- Data Repository
- About Documents
- Debugging and Error Handling
- The Plug-in Bar
- About Printing
- About Processes and Subprocesses
- Using Scripts
- Special Workflow Types
- About Tasks
- Task Properties
- Variable Properties
- Working With Variables
- About Configurations
- About Related Programs and Services
- The Interface
- Customizing the Workspace
- PlanetPress Workflow Button
- The Configuration Components Pane
- Components Area Sections
- Processes and Subprocesses
- Manipulate Global Variables
- Connect Resources
- PPS/PSM Documents
- Associate Documents and PlanetPress Printer Queues
- Using the Clipboard and Drag & Drop
- Rename Objects in the Configuration Components Pane
- Reorder Objects in the Configuration Components Pane
- Grouping Configuration Components
- Expand and Collapse Categories and Groups in the Configuration Components Pane
- Delete Objects and Groups from the Configuration Components Pane
- Other Dialogs
- The Debug Information Pane
- The Message Area Pane
- The Object Inspector Pane
- The Plug-in Bar
- Preferences
- Other Preferences and Settings
- General appearance preferences
- Object Inspector appearance preferences
- Configuration Components Pane appearance preferences
- Default Configuration behavior preferences
- Notification Messages behavior preferences
- Sample Data behavior preferences
- Network behavior preferences
- PlanetPress Capture preferences
- OL Connect preferences
- PDF Text Extraction Tolerance Factors
- General and logging preferences
- Messenger plugin preferences
- HTTP Server Input 1 plugin preferences
- HTTP Server Input 2 plugin preferences
- LPD Input plugin preferences
- Serial Input plugin preferences
- Telnet Input plugin preferences
- PlanetPressFax plugin preferences
- FTP Output Service preferences
- PlanetPress Image preferences
- LPR Output preferences
- PrintShop Web Connect Service preferences
- Editor Options
- The Process Area
- Zoom In or Out within Process Area
- Adding Tasks
- Adding Branches
- Edit a Task
- Replacing Tasks, Conditions or Branches
- Remove Tasks or Branches
- Task Properties Dialog
- Cutting, Copying and Pasting Tasks and Branches
- Moving a Task or Branch Using Drag-and-Drop
- Ignoring Tasks and Branches
- Resize Rows and Columns of the Process Area
- Selecting Documents in Tasks Links
- Highlight a Task or Branch
- Undo a Command
- Redo a Command
- The Quick Access Toolbar
- The PlanetPress Workflow Ribbon
- The Task Comments Pane
- Additional Information
- Copyright Information
- Legal Notices and Acknowledgements
make the condition False whenever a critical alert is detected, regardless of its type.
Select Non-critical alert to choose a specific non-critical alert in the Detected error
box. Select Critical alert to choose a specific critical alert in the Detected error box.
Select Do not test if you only want to test the printer status (above).
l
Detected error: Select a specific non-critical or critical alert. Note that this box is
only displayed if you selected either Non-critical alert or Critical alert in the Alert
Status box.
l User Defined (displayed when User Defined is selected in the Condition Type box)
l
MIB OID number: Enter the Management Information Base Object Identifier
corresponding to the object you want to test. Vendors of SNMP compliant devices
sometimes list MIB OIDs in their documentation.
l
Test: Click to test communication with the device and the MIB OID number.
l
Operator: Select the operator used to test the condition.
l
Value: Enter a specific object status. Vendors of SNMP compliant devices
sometimes list possible object states in their documentation.
l
Invert condition result: Select to toggle the result of the whole SNMP condition
(true becomes false and vice versa).
Management Information Base Object Identifiers
A Management Information Base (MIB) is a database of Object Identifiers (OIDs) that can be
used to monitor device objects using SNMP. An MIB OID can point be a printer tray, cartridge or
hard disk, or to modem mode. Using an SNMP condition, PlanetPress Workflow can
communicate with a device located at a given IP address and request the status of the object
identified by a given MIB OID number. Object Identifiers are typically assigned and registered
by device manufacturers. They are based on a standard known as Abstract Syntax Notation
One (often referred to as the ASN.1 standard).
On Error Tab
The On Error tab is common to all tasks. Details can be found in the" Task Properties Dialog"
on page731.
By default, any action task, branch, splitter or condition that generates an error will simply be
ignored, and the task just under it (not within a branch)will be given control of the job file
without any modification. Any initial input task that generates an error will stop the process from
running as a whole, and output tasks will not generate output. The On Error tab can be used to
overwrite the default behaviors.