2022.1

Table Of Contents
Warning
The JSON format is not validated by the plugin; it is passed as is to the
server.
l
Runtime Parameters: The runtime parameters defined in the selected template are
displayed and their values can be set here. (See Runtime parameters in the Online Help
of OL Connect.)
Right-click the field to open the contextual menu that allows to select variables, data and
lookup functions (see "Data selections" on page54).
If the template name is dynamic, you must enter the name (or select a variable that
contains the name) and set the value of all runtime parameters that may occur in the
template.
If a runtime parameter is defined in a template, but not set in the task properties, an error
will be raised. Note that it is not possible to change a parameter's type here; that can only
be set in the template itself.
At runtime, Workflow passes the parameter values as strings, and the type defined in the
template will be used to try and parse the input parameter value. In order to make this
work: Boolean values need to be entered as either “true” or “false”. (When the comparison
actually occurs, it will be a full Boolean comparison. Thus it can compare this runtime
parameter with Boolean data values that are stored as 0/1 in data fields.) Numeric string
values need to be parseable as a number (either a whole integer or decimal value). Dates
should be in an ISO8601 compatible format (e.g. 2019-10-15) or use the current Windows
Locale date settings options. The latter is not recommended as it requires all computers in
the cluster have the same locale data format.
Email Info tab
l
Sender Address: Enter the email address that appears in the "From" field of the email.
Alternatively you may enter the sender's name and email address in the following format:
John Smith <johnsemail@hisserver.com>. It depends on the email client which
information gets displayed: the sender's name or email address, or both.
l
Mail host: Enter the address of the SMTP server through which emails should be routed.
The address can include a port number. This information should be available from your IT
staff.
l
Send emails to sender (test mode): Check to ignore the email address from each record
and send all emails to the address entered in the Sender Address field instead.
Page 557