2020.1

Table Of Contents
ACE, install the latest MS Access Database Engine 2016 Redistributable
(https://www.microsoft.com/en-us/download/details.aspx?id=54920). Otherwise, using
ACE in one or more self-replicating processes in a Workflow configuration can cause
Workflow to crash.
In the meantime Objectif Lune would like to apologize to any customers affected by this
problem and for any inconvenience caused. For more information, please contact your local
support team.
Data Repository error
The Push to Repository task, as well as the corresponding repository API calls SetValue() and
SetValueW() may on rare occasions fail with an unexpected error (517), caused by the Write
Ahead Logging (WAL) journal mode.
The workaround is to disable WAL journal mode:
1. Create the "Repository" key in \HKEY_LOCAL_
MACHINE\SOFTWARE\WOW6432Node\Objectif Lune\PlanetSuite\PlanetWatch\8.0\ if it
does not exist.
2. Add a new DWORD32 value in Repository key named SQliteWALJournalMode and set it
to 0.
3. Whenever switching the registry key from 1 (WAL) to 0 (DELETE), make sure the -shm
and -wal files are removed from the Repository folder.
4. Restart the PPWatch service.
Other known issues
l Anoto Pen Director 2.8 is not supported on Windows Server 2012 and Windows 10.
l 22356: Using the PT-PT setting to perform ICR on AlphaNumeric fields may not work
properly. If you encounter the issue, use the PT-BR setting instead, or use another
PlanetPess Field in your document design.
l 21962: Barcode scanner task may have issues reading 2-D barcodes printed/scanned
with low resolution. Make sure the scans and the original printed output are at least
300DPI (600 or better recommended)
l 21405: When printing through a Windows printer driver on Windows Server 2008 or
Windows Server 2008 R2, the Job Owner setting is ignored. This is caused by a
documented issue in those two Operating Systems. Microsoft has provided no reason nor
Page 26