2019.2

Table Of Contents
from JET to ACE (change the Data Source). As an example: in Windows 10: Change the
Excel File ODBC driver from ODBCJT32.dll to ACEODBC.dll. (Naming may vary from
versions of the OS but the basics stay the same.) Important: Before switching from JET to
ACE, install the latest MS Access Database Engine 2016 Redistributable
(https://www.microsoft.com/en-us/download/details.aspx?id=54920). Otherwise, using
ACE in one or more self-replicating processes in a Workflow configuration can cause
Workflow to crash.
In the meantime Objectif Lune would like to apologize to any customers affected by this
problem and for any inconvenience caused. For more information, please contact your local
support team.
Other known issues
l 76038: If the Render Email Content plugin receives JSON input and outputs Metadata,
only 1 record will be written to the Metadata. This issue is fixed in version 2020.1.
l 75608: The custom error message, defined in the Respond on error field of the HTTP
Server Input and NodeJS Server Input's task properties, was intended to be sent to the
client as the output file in case the process encounters an error and is unable to send a
reply that includes the actual output file; however, the custom message is not used. This
issue will be fixed in PlanetPress Workflow version 2020.1.
l Anoto Pen Director 2.8 is not supported on Windows Server 2012 and Windows 10.
l 22356: Using the PT-PT setting to perform ICR on AlphaNumeric fields may not work
properly. If you encounter the issue, use the PT-BR setting instead, or use another
PlanetPess Field in your document design.
l 21962: Barcode scanner task may have issues reading 2-D barcodes printed/scanned
with low resolution. Make sure the scans and the original printed output are at least
300DPI (600 or better recommended)
l 21405: When printing through a Windows printer driver on Windows Server 2008 or
Windows Server 2008 R2, the Job Owner setting is ignored. This is caused by a
documented issue in those two Operating Systems. Microsoft has provided no reason nor
workaround for the problem, therefore PlanetPress Workflow cannot circumvent the issue.
l Under Windows 2000, the SharePoint output task does not work with SharePoint 2010.
Under the same OS, the PlanetPress Capture ICR does not work due to the .NET 3.5
requirement.
Page 26