7.4

Table Of Contents
Properties
Capture Fields Processor action task properties are as follows:
l PGCName: This value will be added to the output metadata, as well as the Capture Database, to link the PGCto the
document it updates.
l Pattern sequence group
l Type:Specify from where the Pattern Sequence should be taken.
l None:Do not use a Pattern Sequence.
l Pen Information:Use the Pattern Sequence assigned to the pen in the PlanetPress Capture Database.
l Custom:Overwrite the pen's information and specify a Pattern Sequence manually or use a data selec-
tion.
l Custom Pattern Sequence:If you choose Custom in the Type drop-down, enter a manual Pattern
Sequence or a data selection that contains the Pattern Sequence to be used.
l Fail if new ink is found on non-rewritable fields:Check to trigger the On Error tab if and when a field set as
"Disable Rewriting" receives ink in a new session.
l Ignore out of bounds ink data:Check to continue processing even if receiving a PGCthat causes ink to be outside
of any Capture Field to appear. This may happen if updating the wrong document. When out of bounds ink is found, the
document will be set in the "Error"status. (see note below)
l Split PGCby document:Check to treat each document as a separate PGCfile. This removes the need to use a Cap-
ture PGCsplitter before this task, however the PGCSplitter remains useful when using self-replicating processes to
accelerate PGCprocessing.
When the "ignore out of bounds ink data"option is checked, this option modifies the way that the On Error tab reacts.
When a single split is processed and generates an error, only that split triggers the On Error tab. The other splits con-
tinue processing as usual. If another split generates an error, it also triggers the On Error tab.
Examples &Use Cases
This task is put into effect in the following use cases and example processes:
l Basic Functional Capture Workflow
l Capture Web Manager Workflow
On Error Tab
The On Error Tab is common to all tasks. Details can be found on Task Properties Dialog.
If storing the message or ID, if they are store in a jobinfo they will be available in any error handling process where errors are
being forwarded. In all cases, if your process continues after the error, the contents of the variables selected in this window
will be available for the rest of your process, or whenever they are overwritten.
Common Errors
Though some error messages are specific to a task in particular, others may apply to any and all tasks because they are
related more to the system than to PlanetPress itself. Some examples would be W3813, W3830, W3991, W4005. These cor-
respond to issues such as not having any space to write files, permission errors on folders or files, etc.
Capture PGC Splitter
The Capture PGCSplitter task can be used to separate each document into its own PGCfile so they can be processed sep-
arately. The splitter then sends each document PGCto the next action, which should be the Capture Fields Processor task.