7.0

Table Of Contents
Protocol options group
Log all Winsock and network messages: Select to have PlanetPress Watch/Server keep a
log of all Winsock and other network messages that occur through the LPD service. These
are messages related to jobs being sent from other systems through LPR, and being
received by PlanetPress Watch/Server via LPD. Since these messages can accumulate, you
have the option of not logging them. Log files are kept in the Log folder, which is located in
the PlanetPress Suite installation folder. They are named lpddate.log, where date is the
current date in the yyyymmdd numerical format. Note that changing this option also affects
the log displayed in the PlanetPress Suite Service Console.
No source port range restriction: Select to remove any restrictions on the port of the LPR
client computer that PlanetPress Watch/Server accepts data files from. Clear to have
PlanetPress Watch/Server only accept data files sent from ports ranging between 721 and
731 on the LPR client computer.
Strict RFC 1179 control file: Select to disable control file extensions the LPD service
implements for some flavors of UNIX and LPR. This enforces the basic Line Printer Daemon
protocol.
Enable BSD compatibility mode: Select to have the LPD service emulate a BSD UNIX server.
Although RFC 1179 is supposed to describe the BSD LPD/LPR protocol, and the LPD input in
PlanetPress Watch/Server is RFC1179-compliant, there are some incompatibilities between
the RFC and the BSD implementation. This option compensates for some of these
incompatibilities. If you are not sure about the source of your output, clear this option.
LDP settings group
Timeout (sec): Set the time in seconds the PlanetPress Watch process waits for the
transfer of bytes in the data file before ending the transfer of this file. The default value for
the Time-out property is 7200 seconds (2 hours). On a time-out, partially received data
files are not passed to the rest of the process; the LPD input resets and is ready to receive
further data files. Log messages include the time-out duration.
Related topics:
Change Languages (Page 269)
Change your User Options (Page 269)
Change your Script Editor or XSLT Editor User Options (Page 270)
General User Options (Page 271)
Object Inspector User Options (Page 272)
Configuration Components Area User Options
Default Configuration User Options (Page 273)
Notification Messages User Options (Page 274)
Sample Data User Options (Page 277)
Network User Options (Page 278)
Logging User Options (Page 277)
Messenger User Options (Page 267)
HTTP Server Input User Options (Page 280)
Serial Input Service User Options (Page 283)
Telnet Input User Options (Page 284)
FTP Output Service User Options (Page 285)
LPR Output User Options (Page 262)
Editor Options (Page 258)
Advanced Configurations and Options - Detailed Directions
Objectif Lune Inc. © 2009 282