2019.1

Table Of Contents
these options won't apply to the Additional Content added to the physical N-
Up sheet.
l
Left: Enter the distance between the left margin of the page and the Barcode, in
either metric (cm/mm), inch (in) or point (pt) values.
l
Bottom: Enter the distance between the bottom margin of the page and the
Barcode, in either metric (cm/mm), inch (in) or point (pt) values.
l
USPSIMB Properties group:
l
Track height: The height of the small vertical centre tracking bars, in inches (in).
Value must be between 0.039 and 0.057 inches.
l
Ascender height: The height of the ascender bar.
This also determines the height of the descender bar and full height bars, in inches
(in). Value must be between 0.082 and 0.111 inches.
l
Module width:Thickness of each bar in the Barcode, in inches (in). Value must be
between 0.015 and 0.025 inches.
l
Interchar gap size:The gap between the bars, calculated as a ratio of the module
width, where a value of 1.0 equates to a gap width the same as the module width.
Value must be between 0.012 and 0.04 inches.
l
Print human readable text: Check to add a textual version of the Barcode
data.
l
Placement: Use the drop-down to select whether to place the human
readable text above or below the Barcode.
l
Font name: Use the drop-down to select the font with which to display the
human readable text.
Note
Vertically-oriented fonts (fonts whose typeface name begin with the at
(@) character) are not supported in Connect.
l
Font size: Enter a font size for the human readable text.
Page 1191