1.6

[<JobID>][<Printer Name>] <Message>
Stopping and restarting the OLCS Notifier
To stop the OLCS Notifier, right-click the icon in the notification area and select Exit.
To restart it, either click Taskbar Notifier in the Start menu (under Objectif Lune), or run it from
the folder:
%programfiles(x86)%\Objectif Lune\CPD\App
Changing the UDP communication Port
Each OL Connect Send Printer Driver sends its messages to the OLCS Notifier via UDP. By
default port 8090 is used, but it can be modified by setting a different port number in the registry
under:
l HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Objectif
Lune\ConnectSend\TaskbarNotify on 64bit Windows
l HKEY_LOCAL_MACHINE\SOFTWARE\Objectif Lune\ConnectSend\TaskbarNotify on
32bit Windows
The key must be named UDPPort and must be of type REG_SZ.
The OLCS Notifier will check this entry when it is (re)started and keeps it as long as it is
running. The OL Connect Send Printer Driver is checking this entry on each job transfer.
Note
A change of the UDP port requires a restart of the OLCS Notifier to become active.