SECTION 5 FIRE FIGHTING MEASURES
Flashpoint / Method: N/A
Flammability: LEL = N/A, UEL = N/A
Extinguishing
Media: Use a water fog or CO2 to extinguish fire.
Special Fire Firefighters should wear positive pressure self-contained
Fighting breathing apparatus and full protective clothing for fires in
Procedure: areas where chemicals are used or stored
Unusual Fire and Vinyl film will burn if exposed to flame. Burning in an
Explosion open flame may yield toxic hydrogen chloride gas and metal
Hazards: oxides.
Hazardous Combustion will produce toxic and irritating vapors including
Decomposition hydrogen chloride, metal oxides, CO and CO2.
Products:
SECTION 6 ACCIDENTAL RELEASE MEASURES
Spill or Collect material and remove to disposal container. Observe all federal,
Leak state and local laws.
Procedures:
SECTION 7 HANDLING AND STORAGE
Handling: Avoid contact with eyes, skin and clothing.
Storage: Store in a cool, dry, well-ventilated area away from incompatible
materials. Keep containers closed when not in use.
Other: N/A
SECTION 8 ECOLOGICAL INFORMATION
Information: Make sure that use of this product complies with local VOC emission
regulations, where they exist.
VOC Level: N/A