Dimensions Guide

Job Name Item #
Location
Engineer Contractor
PO # Tag
Representative
AIR ADMITTANCE VALVES
TECHNICAL SPECIFICATION
SPECIFICATIONS
The purpose of an Air Admittance Valve is to provide a method of allowing
air to enter the plumbing drainage system without the use of a vent extended
to open air and to prevent sewer gases from escaping into a building. An Air
Admittance Valve is a one way valve designed to allow air to enter the plumbing
drainage system when negative pressures develop in the piping system. The
device shall close by gravity and seal the vent terminal at zero differential
pressure (no flow conditions) and under positive internal pressures.
APPROVALS & LISTINGS
ASSE 1050 & 1051
ICC ESR-1664
NSF Standard 14
IAPMO – Classified Mark
ASTM D 2665/D 2661
International Plumbing Code (IPC) 2003
International Residential Code (IRC) 2003
INSTALLATION
Read installation instructions prior to use of this product. Always consult
local plumbing codes prior to installing an AAV. Individual, branch and circuit
vents are permitted to terminate with a connection to a Sure-Vent
®
AAV. The
Sure-Vent
®
AAV will only vent fixtures that are on the same floor and connect
to a horizontal branch drain. The horizontal branch drain shall connect to
the drainage stack a maximum of four branch intervals from the top of the
stack. The Sure-Vent
®
AAV should be located within the maximum developed
length permitted for the vent. The Sure-Vent
®
AAV must be located a
minimum of 4 inches above the horizontal branch drain and 6 inches above
any insulation material and within 15 degrees of vertical. Every structure in
which plumbing is installed shall have at least one primary stack vent. The
stack vent should run as directly as possible from the building drain through
to the open air.
Apply approved pipe joint compound or thread seal tape to the male threads
of the valve. Remove protective sleeve after installation.
Oatey Co. | 20600 Emerald Parkway, Cleveland, OH 44135 | P: 1.800.321.9532 | oatey.com
FEATURES & MATERIALS
Access BIM/Revit content through www.oatey.com
Tension
Membrane
Silicone
Sweet Spot
Sweet Spot
technology opens at -0.01 psi
and seals at 0 psi and above
Screening Screening on air inlets to guard the seal
Grip
Protective sleeve provides grip for installation
and keeps valve free from debris
Tested
100% functionally tested at ¼" H
2
O and 30" H
2
O
ensuring trouble free performance
Warranty Limited Warranty
6/19

Summary of content (4 pages)