Specification

Technical Specification
Clear Primer
Oatey Co.
4700 West 160 th St.
Cleveland, OH 44135
Phone: 1-800-321-9532
Phone: 1-800-321-9535
Visit www.oatey.com for Update
Page 3 of 3
Store and use at temperatures between -15°F and 110°F. At temperatures outside of this range, special
care must be taken to prepare good joints and prevent exposure to solvents. Stir or shake before using; if
jelly-like, don’t use. Do not thin.
1. Cut pipe ends square, chamfer and clean pipe ends.
2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If pipe bottoms, it
should be snug.
3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a
natural bristle brush or roller.
4. Apply thoroughly to inside of the fitting socket and to the outside surface of the pipe to the depth of
the fitting. Apply a second coat of primer to fitting socket.
5. While primer is still wet use an appropriate solvent cement for the pipe being joined. Follow application
instructions from cement can.
DO NOT TEST WITH AIR.
Revision Date: 3/15/2013