Suggested Specification
Pressure drinking water cooler shall deliver at least 10 gph
of water at 50ºF (10ºC) cooled from 80ºF (26.7ºC) inlet water at
90ºF (32.2ºC) ambient. Bubbler shall have flexible guard, have a
non-squirt feature and a lever handle shall activate water flow.
Bubbler shall provide smooth steady water flow by means
of
integral regulator that operates from 20 to 120 PSI supply
pressure. Evaporator shall be high efficiency tank type and shall
be encapsulated in insulation. R-134a refrigeration system shall
be hermetically sealed and refrigerant flow shall be capillary tube
controlled. An adjustable thermostat having an off position shall
control refrigeration system. Stainless steel top shall have an
integral drain strainer. Exterior panels shall be powder coated
galvanized steel (standard finish) or stainless steel (optional
finish). Potable water system components shall comply with the
Safe Drinking Water Act Amendments, the 1988 Lead Contami-
nation Control Act and shall be Certified to NSF/ANSI 61,
Section
9. Cooler shall be Listed by Underwriters’ Laboratories In
c. to
U.S. and Canadian safety standards.
Model
P10CP delivers 10 gph of chilled drinking water
Standard Features
> Waterways are Lead-Free in Materials and Construction
> Bubbler with activation lever
> Stainless steel top
> Heavy-gauge steel cabinet with seperate galvanized steel base
> High-efficiency cooling tank and coil.
> Refrigerant R-134a
> Product Certified to NSF/ANSI Standard 61,
Annex G (AB1953)
> Limited 5-Year Warranty
Finishes
> Standard Cabinet Finish: Sandstone powder coated paint
on galvanized steel
> Optional finishes at additional cost: Stainless Steel and
optional powder coated finishes.
Specifications subject to change without notice
* Industry Standard Rating Condition 80°F inlet water temperature.
** Special export models available, operable on 220-240 volts, 50/60 Hertz. cULus certification not applicable.
Installation
> Prior to roughing-in, consult
local, state and federal codes
> Shipped with complete
instructions
Options
> Push Handle 029603-004
> Push Back 029603-005
> Push Down 029603-006
> Kit 031505-001 is required for Field
Installation of the above glass fillers
> Foot pedal operated
Components in this cooler are lead free as defined
by the Safe Drinking Water Act Amendments of
1986, and the Lead Contamination Control Act of
1988.
Limited 5-Year Warranty (Continental limits of the United
States and Canada): Five years on the sealed refrigeration
system and most components parts. Detailed warranty
certificate enclosed with each water cooler; sample copy
available upon request.
Export Warranty: One year on sealed refrigeration system
and most parts. Four-year replacement contract on sealed
refrigeration system. Detailed warranty certificate enclosed
with each water cooler; sample copy available upon
request.
Product Certified to NSF/ANSI Standard 61, Annex G
(weighted average lead content of <=0.25%) and is in
compliance with California's Health & Safety Code Section
116875 (commonly known as AB1953).
Models covered by this specification comply with all known
Plumbing Codes. Listed by Underwriters’ Laboratories to
U.S. and Canadian standards and European Union
Directives.
Model
Rated Capactity
GPH
50° F Drinking Water
90° F Ambient Air Temp*
Base Rate
GPH
Pre-Cooler Hot ’N Cold™
Model
Compr.
HP
Full Load
Amps
Rated
Watts
115 Volts, 60 HZ
Glass Filler
Acc. Option
Cabinet
Color Finish
Net Wt.
Approx.
5.0 No 1/3 5.6
P10CP** Yes Yes 70 Lbs.
5.0
No
510