Instructions for use
Table Of Contents
- Aquarius Fountain Set Classic 750, 1000, 2000, 3000, 4000
- □ A, B
- DE
- EN
- FR
- NL
- ES
- PT
- IT
- DA
- NO
- SV
- FI
- HU
- PL
- CS
- SK
- SL
- HR
- RO
- BG
- UK
- RU
- CN
EN
15
Malfunction remedy
Malfunction
Possible
cause
Remedy
Pump does not run
No mains voltage
Check the mains voltage.
Impeller unit blocked Clean the impeller unit
Insufficient delivery rate Impeller unit running slug-
gishly
Clean the impeller unit
Filter housing clogged Clean the filter housing.
Pressure loss in the hose too
high
Reduce the hose length and
connecting pieces to a mini-
mum
Route hose in a straight line
Unit switches off after a short
running period
Water temperature too high Observe the maximum water
temperature of +35
C
Unit is overloaded
Remove blockage
The unit will switch on
again automatically as soon
as it has cooled down.
The water pattern is uneven or
incomplete
Nozzle is blocked
Clean nozzle
Technical data
Unit data
Aquarius
Fountain Set Eco
750
1000
2000
3000
4000
Rated voltage AC V 230 230 230 230 230
Mains frequency
Hz
50
50
50
50
50
Power consumption
W
9
11
18
26
42
Protection type IP 68 IP 68 IP 68 IP 68 IP 68
Max. pump capacity
l/h
720
1000
2100
3000
4000
Max. water column
m
1.1
1.3
2.1
2.5
2.9
Max. pump immersion depth m 2 2 2 2 2
Water feature connection
G1
G1
G1
G1
G1
Stepped hose adapter
mm
13/19/25
13/19/25
13/19/25
13/19/25
13/19/25
Dimensions Length mm 205 205 205 205 205
Width
mm
180
180
180
180
180
Height
mm
140
140
140
140
140
Weight kg 1.8 1.8 2.0 2.2 2.7