User MANUAL Imaging Tables CFPMFXH CFPMFXH CFPM100 CFPM100 integrated headrest top rectangular top integrated headrest top rectangular top CFPM300 CFPM300 CFPM400 CFPM400 CFPM301 CFPM301 CFPM401 CFPMB301 integrated headrest top integrated headrest top integrated headrest top integrated headrest top rectangular top rectangular top rectangular top rectangular top - Bariatric Version CFPM401 rectangular top CFUR301 Urology Table CFLU401 Lithotripsy Table CFUR401 Urology Table made
© Copyright 2007 OAKWORKS® , Inc. Notice This manual was originally drafted and approved in the English language. Printed in USA All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of OAKWORKS®, Inc. OAKWORKS® is a registered trademark of OAKWORKS®, Inc. The information contained in this document is subject to change without notice and should not be construed as a commitment by OAKWORKS®, Inc. OAKWORKS®, Inc.
Table of Contents Product Use Description ................................................................................................................1 Important Safety Instructions Symbol Identification...................................................................................................................1 Contradictions...............................................................................................................................1 Safety Instructions .........................
Product use description / important safety instructions product use description Oakworks® Imaging Tables are radiographic tables intended for use with mobile or compact stationary C-arm Imaging Systems. It is ideally suited for pain management imaging and therapeutic procedures. These tables are suitable to use for diagnostic x-ray imaging and imaging during therapeutic procedures such as spinal injections, vertebroplasty procedures and other pain management procedures.
Important Safety instructions important safety instructions caution Read and Save These Instructions After unpacking your table, inspect it thoroughly for damage. If you suspect a problem do not use the table and call our customer service department at 800-916-4612. Improper use of this device can cause injury. Be sure to read all operating instructions prior to use. Weight limit (patient and accessories): 227 kg / 500 lbs. distributed evenly. (Bariatric Table only: 340 kg / 750 lbs.
Important Safety instructions WARNING To reduce the risk of burns, fire, electric shock or injury to persons: 1. Unplug this furnishing from the electrical outlet before cleaning. 2. Unplug from outlet before adding or removing parts. 3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use. 4. Keep the cord away from heated surfaces. 5.
Product Description CFPMFXH 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Locking Casters Standard Specifications options Fixed Height 5” (13cm) Locking Casters 37” (91cm) Choice of Tabletop: - Integrated Headrest 22” (56cm) W x 84” (214cm) L - Rectangular 24” (61cm) W x 80” (203cm) L Table Voltage Options 120V/60Hz or 230V/50Hz Table Capacity 500 lbs. (227 kg.
Product Description CFPM100 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Electronic Lift Tower Emergency Stop Integrated Face Rest with Crescent Face Pad Locking Casters Standard Specifications options Height Motion Powered 22”-40” (56-102cm) 5” (13cm) Locking Casters Foot Control height motion International Electric Configurations Choice of Tabletop: - Integrated Headrest 22” (56cm) W x 84” (214cm) L - Rectangular 24” (61cm) W x 80” (
Product Description CFPM300 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 26”-44” (66-112cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-12° Trendelenburg International Electric Configurations Motion 3 Powered ±15 Lateral Tilt Accessories Hand & Foot Control All powered m
Product Description CFPM400 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 26”-44” (66-112cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-12° Trendelenburg Tilt International Electric Configurations Motion 3 Powered ±15° Lateral Tilt Accessories Motion 4 Powered 10” (25cm)
Product Description CFPM301 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 25”-43” (64-109cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-11° Trendelenburg International Electric Configurations Motion 3 Powered 10” (25cm) Longitudinal Travel Accessories Hand & Foot Control
Product Description CFPMB301 - Bariatric 24” x 80” Bariatric Carbon Fiber Top with Removable Table Top Pad Hand Rail Electronic Lift Tower Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 26”-44” (66-112 cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-11° Trendelenburg International Electric Configurations Motion 3 Powered 10” (25cm) Longitudinal Travel Accessories Hand & Foot Control All powered motions Carbon Fiber Arm Board (Standard or Wi
Product Description CFPM401 24” x 80” rectangular top Carbon Fiber Integrated Headrest Top with Removable Table Top Pad Hand Rail Integrated Face Rest with Crescent Face Pad Electronic Lift Tower Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 26”-44” (66-112cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-12° Trendelenburg Tilt International Electric Configurations Motion 3 Powered 10” (25cm) Longitudinal Travel Accessories Motion 4 Power
Product Description CFLU401 - Lithotripsy/Urology Top T-rail Carbon Fiber Top with Removable Table Top Pad (along each side) L a te r a l E x te Short Extension Hand Rail (4) n s io n s (under end) End Extension Emergency Stop Locking Casters Standard Specifications Motion 1 Powered 27”-45” (66-112cm) Height Range Urology Bag Hoop Clips onto T-rails (bag not included) Motion 2 Powered +15°/-12° Trendelenburg Tilt Intregrated T-rails .38” (1cm) Thick x 1.
Product Description CFUR301 - Urology Top Urology Carbon Fiber Top with Removable Table Top Pad Hand Rail (at end) Electronic Lift Tower T-rail Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 26”-44” (66-112cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-11° Trendelenburg Tilt International Electric Configurations Motion 3 Powered 10” (25cm) Longitudinal Travel Accessories Hand & Foot Control All powered motions Carbon Fiber Arm Board (S
Product Description CFUR401 - Urology Top Urology Carbon Fiber Top with Removable Table Top Pad Hand Rail (at end) Electronic Lift Tower T-rail Emergency Stop Locking Casters Standard Specifications options Motion 1 Powered 27”-45” (69-114cm) Height Range 5” (13cm) Locking Casters Motion 2 Powered +15°/-11° Trendelenburg Tilt International Electric Configurations Motion 3 Powered 10” (25cm) Longitudinal Travel Accessories Motion 4 Powered ±4” (10cm) Lateral Travel Carbon Fiber Arm Board
installation The Imaging tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible. Be sure access to plug is not blocked for disconnecting the table from power.
directions for use foot control - one motion Used to raise and lower the height of the table. foot control - three motion Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion. Control functions dependent upon table’s features. foot control - four motion Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Motion.
directions for use hand control - three motion Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion. Control functions dependent upon table’s features. hand control - four motion Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Motion.Control functions dependent upon table’s features.
directions for use bubble levels Bubble levels are installed on the handle end of the table to aid the operator to determine the horizontal plane. angle indicator Standard on CFLU401, CFUR401 and CFUR301 Tables. Optional on all other Imaging Tables. To use angle indicator, simply press “on/off” button on the left side of the indicator. NOTE: Do not press “zero” unless table is in the horizontal position.
directions for use remove / replace the table top pad caution Make sure the top is not in motion when removing / replacing the table top pad. Remove Table Pad by pulling flaps at the ends & sides of the table until the hook and loop fastener becomes unanchored. Replace pad by first centering on the table and then pressing flaps in place, anchoring with the hook and loop fasteners.
directions for use locking casters use All four casters should be locked at all times during use with a patient. locking the casters 1. Place your shoe on the end of the casters locking tab. 2. Press firmly downward until you here a clicking noise and the caster is locked. un-locking the casters 1. Place your shoe on top of the casters locking tab. 2. Press firmly inward and downward until you here a clicking noise and the caster is unlocked.
directions for use weight capacity & patient use The Oakworks® table top is rated at 500 lb. (227 kg) load evenly distributed. (Bariatric table is rated at 750 lbs. (340 kg)) To minimize any risk to the patient, do not allow the patient to sit on the face rest area beyond the warning line on the table top. Casters should be locked when patient is mounting or dismounting the table. Table should be flat when mounting and dismounting. Patient should mount and dismount near the lifting column.
directions for use lateral extensions - lithotripsy/urology & urology tops caution Do not sit on any extensions. Weight Limit: 200 lbs. / 91 kg. There are four lateral extensions for the Lithotripsy table. (2 - 8” x 11”, 1 - 8” x 14” and 1 - 8” x 24”). 8” x 11” (20 x 28cm) 8” x 24” (20 x 61cm) 8” x 14” (20 x 36cm) 8” x 11” (20 x 28cm) The 2 - 8” x 11” (20 x 28 cm) are angled and designed to be used on both sides of the Lithotripsy opening.
directions for use end extensions - lithotripsy/urology & Urology tops caution Do not sit on any extensions. Weight Limit: 200 lbs. / 91 kg. There are extensions which can be inserted on either end of the table. (1) - 23” x 28” (58 x 71cm) and (1) - 23” x 16” (58 x 41cm) - Lithotripsy/Urology, (1) - 23” x 28” (58 x 71cm) - Urology To Insert Extension Slide the two “arms” into the ends of the table top. Push fully in and extension arms will drop slightly into a locking pin.
directions for use carbon fiber arm board (accessory) caution Do not place undue weight or downward pressure on the Carbon Fiber Arm Board. It is a positioning device for the arms and should not be used as leverage to get on or off the table. Injury can occur. DO NOT exceed 30 lbs. (14 kg.) of load on the Support Section. Injury can occur. Use This radiolucent device can be used with any flat support surface where ionizing radiation (x-ray) is utilized for imaging.
directions for use spine positioning system ii (accessory) For directions on the use of the Spine Positioning System, see publication “Spine Positioning System” Part number MMMMNUP0003 Contoured Torso Support Pad Crescent Face Rest Pad Radiolucent frame with adjustable face rest Contoured Torso Wedge 8” x 22” x 2” (20 x 56 x 5cm) Large rectangular adjuster pad 7” x 12” x 1½” (18 x 31 x 4cm) SMALL rectangular adjuster pad 8” (20cm) semiround bolster carry case fluoro extender (accessory) caution Do not
reference usable imaging area - CFPMFXH & CFPM100 Integrated headrest tops only Centered for a-p view: No image oblique 30° view for vertical: No image caudal 30° view for vertical: No image 25
reference usable imaging area - CFPMFXH & CFPM100 rectangular tops only Centered for a-p view: No image oblique 30° view for vertical: No image caudal 30° view for vertical: No image 26
reference usable imaging area - CFPM400, cfpm300, cfpm401 & cfpm301 Integrated headrest tops only Centered for a-p view: No image oblique 30° view for vertical: No image caudal 30° view for vertical: No image 27
reference usable imaging area - CFPM400, cfpm300, cfpm401 & cfpm301 rectangular tops only Centered for a-p view: No image oblique 30° view for vertical: No image caudal 30° view for vertical: No image 28
reference usable imaging area - CFur301 & cfur 401 CENTERED A-P VIEW: Centered for FOP a-p view: 47.0" [119.38cm] 23.3" [59.06cm] NoImage image No 23.0" [58.42cm] 2.0" [5.08cm] TYP 19.0" [48.26cm] oblique 30°30° view forFROM vertical: OBLIQUE VIEW VERTICAL: 47.0" [119.38cm] 23.3" [59.06cm] No Noimage Image 21.0" [53.34cm] 2.8" [6.99cm] TYP 15.5" [39.37cm] CAUDAL 30° VIEW FROM VERTICAL: caudal 30° view for vertical: 41.5" [105.41cm] 20.0" [50.80cm] No Image image No 23.0" [58.42cm] 2.0" [5.
reference usable imaging area - CFLU401 CENTERED A-P VIEW: Centered for FOP a-p view: 47.0" [119.38cm] 23.3" [59.06cm] NoImage image No 23.0" [58.42cm] 2.0" [5.08cm] TYP 19.0" [48.26cm] oblique 30° 30° view for FROM vertical: OBLIQUE VIEW VERTICAL: 47.0" [119.38cm] 23.3" [59.06cm] No No image Image 21.0" [53.34cm] 2.8" [6.99cm] TYP 15.5" [39.37cm] CAUDAL VIEW VERTICAL: caudal 30°30° view for FROM vertical: 41.5" [105.41cm] 20.0" [50.80cm] No Image image No 23.0" [58.42cm] 2.0" [5.08cm] TYP 19.
cleaning & disinfection / inspections / warranty cleaning & disinfection warning Before cleaning with any liquid cleaner be sure to unplug the power cord from the outlet. Use a 10% sodium hypochlorite (bleach) solution or Recommended Disinfectants on all surfaces. Clean all sides of each upholstered section. Follow the directions on the disinfectant and wipe off excess.
model number & serial number model & serial numbers Serial Number Model Number Imaging Table Power Rating US 120 V 60 Hz 8.2 A Class 1 Equipment Duty Cycle: MAX 2 minutes ON 18 minutes OFF 3034177 The model number and serial number are located on the lift column. CONFORMS TO: ANSI/AAMI STD ES60601-1 IEC STD 60601-1-6 Certified to CAN/CSA STD C22.2 No. 60601-1 Part No. 70537-1 rev.
specifications product specifications Weight North America Europe 359-452 lbs. 163-205 kg. Shipping Weight 452-544 lbs. 205-247 kg. Lifting Capacity 500 lbs. (750 lbs. Bariatric) 227 kg. (340 kg. Bariatric) Materials of Construction This product contains no latex. Aluminum Equivalence Aluminum Filtration Equivalence and thickness of Carbon Fiber Tabletop Thickness Non-Bariatric Tops 100 kVp, HVL of 3.6mm = 1.10 (1.35 max) 1.65” (4.2 cm) Bariatric Tops 100 kVp, HVL of 3.6mm = 1.50 (1.
specifications Guidance and Manufacturer’s Declaration - Electromagnetic Emissions All Equipment and Systems (except CFPMFXH) The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment.
specifications Guidance and Manufacturer’s Declaration - Immunity All Equipment and Systems The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment.
specifications Guidance and Manufacturer’s Declaration - Immunity Equipment and Systems that are NOT life-supporting The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment.
User MANUAL OAKWORKS Imaging Tables ® Contact Information: Oakworks® Inc. 923 East Wellspring Road New Freedom, PA 17349 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworksmed.com 3034177 CONFORMS TO: ANSI/AAMI STD ES60601-1 IEC STD 60601-1 3rd Edition IEC STD 60601-1-2 3rd Edition IEC STD 60601-1-6 3rd Edition IEC STD 60601-2-32 Certified to CAN/CSA STD C22.2 No.