2. Terminal Descriptions
1 2 3 4 5 6 7 8 9
10 11 12
ON DIP
L1
L2
SW+ SW-
1 2 3 4 5 6 7 8 9
10 11 12
ON DIP
L1
L2
SW+ SW-
L1, L2: Bus terminal.
SW+, SW-: Door bell call button connection port.
DIP:
Bit-1~7: Used to User Code setting or Extended Address setting(Bit-10 set to
ON).
Bit-8~9: Used to Slave Monitor Address (Bit-10 set to OFF).
Bit-11: Set to ON if the monitor is at the end of the line;Otherwise, set to OFF.
Bit-12: Reserved.
3. Unit Mounting
2
63 inch
1). Fix 2 screws to the wall at a appropriate
height;
2). Connect the system correctly;
3). Attach the audio phone to the bracket.
NOTE:
SEE ADA COMPLIANCE AND OR (AHJ) FOR
PROPER HEIGHT (48”-54”)