Installation Guide
Table Of Contents
After Installation:
Check ignition of cooktop burners.
Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.
Check for gas leaks at all gas connections (using a gas detector, never a flame).
Connect Rangetop to Gas Supply
• Install a manual gas line shut-off valve in the gas line in an easily accessed location
outside the cooktop in the gas piping external to the appliance for the purpose of
turning on or shutting off gas to the appliance.
•
regulator. On models equipped with standard twin burners, install the male pipe
pressure regulator. Use a wrench on the regulator fitting to avoid damage.
•
shut -off valve, taking care to secure the shut -off valve to keep it from turning.
• The gas supply pressure for checking the regulator setting is 6in (Natural Gas) and
11inch (LP gas )connect flexible gas line connector to the regulator on the rangetop.
Position cooktop to permit connection at the shut- off valve.
•
position and turn on the main gas supply valve.
•
instructions .Use some soap water (50% water and 50% soap) or a leak detector at
all joints and connections to check for leaks in the system. Do not use a flame to
check for gas leaks.
•
closing its individual manual shut-off valve during any pressure testing of the gas
supply piping system at test pressure equal to or less than ½ psig (3.5kPa).
Install male 1/2" flare union adapter to 1/2" NPT internal thread elbow at inlet of
thread end of the 1/2" flare union adapter to the 1/2" NPT internal thread at inlet of
Install male 1/2" or 3/4" flare union adapter to the NPT internal thread of the manual
When all connections have been made, check that all range controls are in the “ off ”
Leak testing of the appliance shall be conducted according to the manufacture' s
The appliance must be isolated from the building’s gas supply piping system by
15