User's Manual
12 
INSTALLATION INSTRUCTIONS 
Grounding 
1.  The power cord is equipped with a three-prong (grounding) plug which mates with a 
standard three-prong grounding wall receptacle to minimize the possibility of 
electrical shock hazard from the range.   
2.  All cord connected appliance shall include instructions relative to location of the wall 
receptacle and a warning to the user to disconnect the electrical supply before 
serving the appliance. 
3.  Where a standard two-prong wall receptacle is encountered, it is the responsibility 
and obligation of the customer to have it replaced with a properly grounded 
three-prong wall receptacle. Do not cut or remove the grounding prong from the 
power cord.   
Connect Range to Gas Supply   
1.  Install a manual gas line shut-off valve in the gas line in an easily accessed location 
outside the range in the gas piping external to the appliance for the purpose of turning 
on or shutting off gas to the appliance.   