Owner Manual (Gas Range)

13
Cabinet/Countertop Dimensions (cont.)
Cabinet tolerances ± 1/16" (± 1.6 mm) unless otherwise noted.
23.7" (60.2 cm)
Installed control
Gas and electrical connections at
right rear section of chassis
Cabinet
face
panel overhang
1/7/10" (4.35 cm)
Countertop
Mounting platform
Installed Rangetop - Side View
Gas connection and power cord may be
routed through bottom or back of chassis
IMPORTANT: Use only the downdraft vent models specified.
Increase countertop and overhang
additional 2 1/2" (6.4 cm) min. for
combustible rear wall above
countertop
Non-combustible
rear wall, rear of
mounting platform
1/2" (1.3 cm)
countertop overhang
10" (25.4 cm) min.
to combustible wall
above countertop,
both sides
23.7"
(60.2 cm)
min.
cabinet
depth
Gas/electrical utility cut-out in right rear corner of
mounting platform 11.8" W X 3.93" D (30 cm X 10 cm),
if gas and electrical are routed through bottom
1" (2.5 cm) thick mounting platform min.
Cabinet face
below countertop
overhang
B
Counterop
overhang
1 ” (2.5 cm)
typical
1 7/10
(4.35 cm)
max.
Countertop
Countertop