Datasheet

6.5.4 FlexCAN electical specifications
For supported baud rate, see section 'Protocol timing' of the Reference Manual.
6.5.5 SAI electrical specifications
The following table describes the SAI electrical characteristics.
Measurements are with maximum output load of 50 pF, input transition of 1 ns and
pad configured with fastest slew settings (DSE = 1'b1).
I/O operating voltage ranges from 2.97 V to 3.6 V
While doing the mode transition (RUN -> HSRUN or HSRUN -> RUN ), the
interface should be OFF.
Table 30. Master mode timing specifications
Symbol Description Min. Max. Unit
Operating voltage 2.97 3.6 V
S1 SAI_MCLK cycle time 40 ns
S2 SAI_MCLK pulse width high/low 45% 55% MCLK period
S3 SAI_BCLK cycle time 80 ns
S4 SAI_BCLK pulse width high/low 45% 55% BCLK period
S5 SAI_RXD input setup before
SAI_BCLK
28 ns
S6 SAI_RXD input hold after
SAI_BCLK
0 ns
S7 SAI_BCLK to SAI_TXD output
valid
8 ns
S8 SAI_BCLK to SAI_TXD output
invalid
-2 ns
S9 SAI_FS input setup before
SAI_BCLK
28 ns
S10 SAI_FS input hold after
SAI_BCLK
0 ns
S11 SAI_BCLK to SAI_FS output
valid
8 ns
S12 SAI_BCLK to SAI_FS output
invalid
-2 ns
Communication modules
S32K1xx Data Sheet, Rev. 4, 06/2017
NXP Semiconductors
Preliminary
49