Datasheet
6.5.4 FlexCAN electical specifications
For supported baud rate, see section 'Protocol timing' of the Reference Manual.
6.5.5 SAI electrical specifications
The following table describes the SAI electrical characteristics.
• Measurements are with maximum output load of 50 pF, input transition of 1 ns and
pad configured with fastest slew settings (DSE = 1'b1).
• I/O operating voltage ranges from 2.97 V to 3.6 V
• While doing the mode transition (RUN -> HSRUN or HSRUN -> RUN ), the
interface should be OFF.
Table 30. Master mode timing specifications
Symbol Description Min. Max. Unit
— Operating voltage 2.97 3.6 V
S1 SAI_MCLK cycle time 40 — ns
S2 SAI_MCLK pulse width high/low 45% 55% MCLK period
S3 SAI_BCLK cycle time 80 — ns
S4 SAI_BCLK pulse width high/low 45% 55% BCLK period
S5 SAI_RXD input setup before
SAI_BCLK
28 — ns
S6 SAI_RXD input hold after
SAI_BCLK
0 — ns
S7 SAI_BCLK to SAI_TXD output
valid
— 8 ns
S8 SAI_BCLK to SAI_TXD output
invalid
-2 — ns
S9 SAI_FS input setup before
SAI_BCLK
28 — ns
S10 SAI_FS input hold after
SAI_BCLK
0 — ns
S11 SAI_BCLK to SAI_FS output
valid
— 8 ns
S12 SAI_BCLK to SAI_FS output
invalid
-2 — ns
Communication modules
S32K1xx Data Sheet, Rev. 4, 06/2017
NXP Semiconductors
Preliminary
49