Datasheet
7
CONFIDENTIAL AND PROPRIETARY
J21
Low-side recirculation diode enable
Pin 1-2 Closed Diode is connected to HD
Pin 2-3 Closed Diode is connected to HS
J33 Current measurement selector
Pin 1-2 Closed External operational amplifier is
selected for measure the current
Pin 2-3 Closed Internal operational amplifier is
selected for measure the current
J37 Internal operational amplifier reference voltage selector
Pin 1-2 Closed 2.5 V reference selected
Pin 2-3 Closed 5 V reference selected
J38 Internal operational amplifier reference voltage selector
Pin 1-2 Closed 2.5 V reference selected
Pin 2-3 Closed 5 V reference selected
Default Jumper configuration