The bit time is determined by the oscillator frequency, the baud rate prescaler, and the number of time
quanta (Tq) clock cycles per bit (as shown in Table 12-7 and Table 12-8).
Eqn. 12-1
12.3.4.1 MSCAN Receiver Flag Register (CANRFLG)
A flag can be cleared only by software (writing a 1 to the corresponding bit position) when the condition
which caused the setting is no longer valid. Every flag has an associated interrupt enable bit in the
CANRIER register.
Table 12-7. Time Segment 2 Values
TSEG22 TSEG21 TSEG20 Time Segment 2
0 0 0 1 Tq clock cycle
1
1
This setting is not valid. Please refer to Table 12-35 for valid settings.
0 0 1 2 Tq clock cycles
::: :
1 1 0 7 Tq clock cycles
1 1 1 8 Tq clock cycles
Table 12-8. Time Segment 1 Values
TSEG13 TSEG12 TSEG11 TSEG10 Time segment 1
0 0 0 0 1 Tq clock cycle
1
1
This setting is not valid. Please refer to Table 12-35 for valid settings.
0 0 0 1 2 Tq clock cycles
1
0 0 1 0 3 Tq clock cycles
1
0 0 1 1 4 Tq clock cycles
:::: :
1 1 1 0 15 Tq clock cycles
1 1 1 1 16 Tq clock cycles
76543210
R
WUPIF CSCIF
RSTAT1 RSTAT0 TSTAT1 TSTAT0
OVRIF RXF
W
Reset: 00000000
= Unimplemented
Figure 12-8. MSCAN Receiver Flag Register (CANRFLG)
Bit Time
Prescaler value()
f
CANCLK
------------------------------------------------------
1 TimeSegment1 TimeSegment2++()•=