Jumper Configuration Comment
J24 Removed
J25, J26 Removed
J37, J38 Removed
5.4.2 ISO/IECC 144443-A via external antenna
Figure 16 shows the jumper settings to configure the contactless interface via an IN-
CLA7816 probe connected through DB15 connector.
Figure 16.  ISO/IEC14443 via DB15 connector
Table 11 details the jumper settings for this configuration (ISO/IECC 144443-A via
external antenna).
Table 11. ISO/IEC14443 via DB15 connector
Jumper Configuration Comment
J6 Set to 1-2 Contactless operation enabled with external ID1
antenna through DB15 connector
J7 Set to 1-2 Contactless operation enabled with external ID1
antenna through DB15 connector
J9, J10 Removed
J12 Removed
J13 Removed
J14 Removed
J15 Removed
J16 Removed
J17 Removed
J19 Removed