Operations
Access to the Device
During operations, the user must prevent access to or contact with the device for children, pets, plants, and insects.
Controls and Display Elements SafeSOMmicro
S1: Reset Button
H1: Diagnostic MCU, User defined LED
H2: Diagnostic MCU, User defined LED
H3: Safety MCU Status LED: LED on = Initialization successful
H4: Safety MCU Status LED: LED Blinking = MCU communication OK; LED ON = Error
H5: VDD present
Controls and Display Elements BMS Baseboards
H1: BCC Fault output LED
Jumper Settings BMS Base Board:
P3: Soldering Jumper for Breaker sense control selection:
Short Pin 1+2: BCC (default), Short Pin 2+3: MCU1
P4: Close Jumper to enable CAN Termination
P7: Close Jumper to supply VBAT_AUX from CL30
Connector Description SafeSOMmicro
P1: JTAG Interface Diagnostic MCU
2x5 Pin Header RM 1,27mm
Pin Number Description Pin Number Description
1 3V3 2 TMS
3 GND 4 TCLK
5 GND 6 TDO
7 NC 8 TDI
9 NC 10 /MCU Reset
P2: JTAG Interface Safety MCU
2x5 Pin Header RM 1,27mm
Pin Number Description Pin Number Description
1 5V 2 TMS
3 GND 4 TCLK
5 GND 6 TDO
7 NC 8 TDI
9 NC 10 /MCU Reset